FibeAir
®
1500P
1500HP
1500SP
3200T
High & Ultra High Capacity
Wireless Network Systems
Installation and
Operation Manual
Part ID: BM-0080-0
Doc ID: DOC-00013447 Rev a.03
July 2006

Table of Contents

Questions and Answers

  • G
    gwilliamsAug 17, 2025
    What to do if Ceragon FibeAir 1500P Rx Level is Out of Range?
    • M
      Michaela BartonAug 17, 2025
      If the Rx level of your Ceragon Antenna is out of range, it typically means the RSL is very low, often below -80 dBm, indicating the link is down. First, ensure the issue isn't due to rain, multipath fading, or a lack of line of sight. Next, check your link settings, including TX power and frequency. Then, verify the antenna alignment. If problems persist, consider replacing the local or remote ODU.
  • E
    Elizabeth SparksAug 20, 2025
    What to do if Ceragon FibeAir 1500P Antenna Power Input #1 is Down?
    • H
      Heather FoleyAug 20, 2025
      If Power Input #1 is down on your Ceragon Antenna, it indicates a subrack redundant power feed failure. First, verify that the power input is correctly connected to the -48 VDC supply. Next, check the -48 VDC supply to the subrack. If you're not using a redundant power feed, disable Power Input #1.
  • M
    Matthew GriffithAug 23, 2025
    What to do if Ceragon FibeAir 1500P Power Input #2 is Down?
    • J
      Jared FordAug 23, 2025
      If Power Input #2 is down on your Ceragon Antenna, it suggests a subrack redundant power feed failure. Initiate troubleshooting by confirming that the power input is connected to the -48 VDC supply. Proceed by inspecting the -48 VDC supply to the subrack. If a redundant power feed isn't utilized, consider disabling Power Input #2.
  • K
    Kevin RobbinsAug 26, 2025
    What to do if Ceragon Antenna Tx Level is Out of Range?
    • B
      Brandi DavisAug 26, 2025
      If the Tx level of your Ceragon Antenna is out of range, it means that the ODU cannot transmit the requested Tx power. You can gradually reduce the TX power. If the problem persists, consider replacing the ODU.
  • R
    Ronald LoveAug 28, 2025
    What to do if Ceragon Antenna Cable is Open?
    • M
      Marcus AlvarezAug 28, 2025
      If you encounter an open cable error with your Ceragon Antenna, where the IDM-ODU cable is open, start by checking the IF cable and its connectors. Verify that the ODU N-type connector inner pin is not spliced, and if it is, replace the ODU. If the issue persists, try replacing the IDM or the ODU.
  • M
    Marcus GarciaAug 31, 2025
    What to do if Ceragon FibeAir 1500P Antenna has No Signal from ODU?
    • J
      Joshua WallsAug 31, 2025
      If there is no signal from ODU in your Ceragon Antenna, meaning no Rx (140 MHz) signal, begin by inspecting the IF cable and connectors. Then, verify that the ODU N-type connector inner pin is not spliced. If it is, replace the ODU. If the issue continues, replace the IDM or ODU. For 1500HP, check the BMA connector center pin on both the RFU and OCB to ensure it is not spliced.
  • S
    Steven WangSep 2, 2025
    What to do if Ceragon FibeAir 1500P ODU Temperature is Out of Range?
    • B
      Brandon HernandezSep 3, 2025
      If the ODU temperature of your Ceragon Antenna is out of range (too high or too low), first check the installation conditions. If the temperature issue persists, replace the ODU.
  • W
    Wendy WhiteSep 5, 2025
    How to fix Ceragon FibeAir 1500P Antenna Synthesizer #1/2/3 Unlocked?
    • S
      stephaniekimSep 5, 2025
      If one of the synthesizers is unlocked on your Ceragon Antenna ODU, replace the ODU. In an XPIC configuration, the ODU might synchronize with the mate ODU; if this is the case, check whether the alarm persists in a non-XPIC configuration.
  • S
    Scott WeberSep 8, 2025
    What to do if Ceragon FibeAir 1500P Drawer Internal Power Failure (Board #1)?
    • R
      Rebecca JohnsonSep 8, 2025
      If you experience a Drawer Internal Power Failure (Board #1) on your Ceragon Antenna, note that Board #1 is the MUX card and Board #2 is the Modem card. This alarm can also occur if a drawer in Internal Protection was switched off. Try switching the IDM off and on. If the problem persists, replace the IDM.
  • J
    Jason JohnsonSep 12, 2025
    How to resolve Ceragon FibeAir 1500P Antenna IDU-MUX Inner Communication Failure?
    • A
      Amy RichSep 12, 2025
      If you're experiencing an IDU-MUX inner communication failure with your Ceragon Antenna, where the IDC cannot communicate with the MUX card or the MUX card upload failed, try the following: reset the IDU. Verify the correct software version and interfaces. If the problem persists, replace the IDU.

Summary

Chapter 2 Theory of Operation

FibeAir 1500 P

Explanation of FibeAir 1500P's design for double capacity using a single 28 MHz channel and CCDP mode.

FibeAir 1500 HP

Theory of operation for FibeAir 1500HP, focusing on its RFU capabilities and diversity design.

FibeAir 1500 SP

Theory of operation for FibeAir 1500SP ODU, including its frequency range and capacity.

Chapter 3 Installation

Installing the Antenna and ODU

Detailed procedure for installing the 1 ft (RFS) antenna assembly and ODU.

Initial Antenna Alignment using the Headset

Procedure for performing initial antenna alignment using an audible tone from a headset.

Alignment Verification (checking actual receive level)

Procedure to verify antenna alignment by checking the actual received signal level against expected values.

Installation Verification

Steps to verify the completed antenna installation and initial alignment.

ODU Installation for a 6;7;8 GHz System

Specific installation procedure for ODU in 6/7/8 GHz FibeAir systems using an external diplexer.

6-8 GHz Frequency Diversity and 2+0 System Installation

Installation instructions for 6-8 GHz systems using frequency diversity and 2+0 configurations.

Installing the FibeAir 1500 HP Split-Mount RFU, 1+0;1+1

Procedure for installing the FibeAir 1500HP RFU in a split-mount configuration.

Installing the FibeAir 1500 HP Split-Mount RFU - 2+2, XPIC

Installation procedure for FibeAir 1500HP in a Split-Mount 2+2 XPIC configuration.

Installing the FibeAir 3200 T All-Indoor RFU

Installation procedure for FibeAir 3200T in an All-Indoor configuration.

Installing the FibeAir 1500 SP ODU

Installation procedure for the FibeAir 1500SP ODU in 1+0 and 1+1 configurations.

XPIC Installation and Comissioning

Installation and commissioning procedure for FibeAir 1500 system with XPIC in Co-Channel Dual Polarization.

Chapter 4 Initial System Setup

Initial Setup using the Craft Terminal

Procedures for initial system setup using a craft terminal via serial port connection.

Chapter 5 Operation

CeraView Configuration

Configuration of CeraView utility for operation settings like time intervals and remote hosts.

Chapter 6 Troubleshooting

Troubleshooting Guide

Step-by-step guide for diagnosing and resolving system problems, from symptom definition to solution.

Alarm List Table

Table of trap IDs, descriptions, probable causes, and corrective actions for system alarms.

Fault Isolation using Loopbacks

Procedure for testing link connectivity at various points using loopback functions.

Connection Fault Guide

Guide to identifying and correcting problems related to cable configuration when connecting via CeraView.

Chapter 7 Protection Configuration

Ceragon FibeAir 1500P Specifications

General IconGeneral
BrandCeragon
ModelFibeAir 1500P
CategoryAntenna
LanguageEnglish