Do you have a question about the CERTUSS Junior 80 - 400 TC and is the answer not in the manual?
Explains the meaning of symbols used in the operating instructions.
Defines the intended purpose and limitations of the steam generator.
Lists relevant standards and regulations for the steam generator.
Specifies the necessary qualifications and training for personnel.
Outlines the operator's responsibilities for safe operation.
Mentions German regulations for danger assessment.
Classifies steam generators based on pressure and volume.
Details how to assign and instruct personnel for steam generator operations.
Warns about dangers of live electrical parts and safety precautions.
Outlines safety measures for electrical and gas equipment maintenance.
Specifies that spare parts must meet manufacturer's technical requirements.
Provides guidelines for disposing of used lubricants and other materials.
Details possible electrical network connections for the steam generator.
Explains the start-up process and operational sequence of the steam generator.
Details the operational sequence and components of the gas firing system.
Explains gas firing operation with the addition of flue gas recirculation.
Details the operational sequence and components of the oil firing system.
Explains oil firing operation with the addition of flue gas recirculation.
Describes the operation and features of the Thermotimat control system.
Details the automatic start-up and blowdown functions of the Thermotimat system.
Illustrates the installation layout for the Thermotimat system.
Explains operation without constant supervision for up to 24 hours.
Lists the standard equipment for unsupervised operation.
Describes the automatic furnace safety check and shut-down procedures.
Explains operation without constant supervision for up to 72 hours.
Lists the standard equipment for unsupervised operation.
Describes the automatic furnace safety check and shut-down procedures.
Details additional requirements for safe operation beyond 72 hours.
Explains the functions and text displays triggered by touching screen fields and symbols.
Explains how to select and change the display language on the touchscreen.
Covers general installation requirements and points to observe for the steam generator.
Details the procedures for the initial start-up of the steam generator.
Explains how to manually start and stop the steam generator.
Lists prerequisites for starting the generator without the Thermotimat system.
Guides through the process of starting the steam generator via the touchscreen.
Details the procedure for switching off the steam generator.
Explains how to activate and program the Thermotimat system.
Lists the conditions required to activate the Thermotimat system.
Guides through the steps to activate and program the Thermotimat system.
Describes manual start/stop operations when Thermotimat is active.
Provides information on abnormal operating states and upcoming maintenance.
Explains the cause and resolution for increased water pressure.
Explains the causes of steam generator overload and potential damage.
Indicates if blowdown did not occur within the programmed time.
Alerts when feed water temperature is insufficient for operation.
Warns about an upcoming automatic controlled shut-down.
Notifies about the end of the 72-hour operation period and required inspections.
Indicates when recurring safety tests are due.
Alerts when boiler maintenance by customer service is due.
Explains how to access stored fault, function, and information messages.
Details how to retrieve stored fault messages that caused shut-downs.
Guides through changing settings like date, time, display, and remote server access.
Explains how malfunctions cause shut-downs and how to view fault causes.
Specifies requirements for boiler feed water quality and temperature.
Provides daily, monthly, and semi-annual testing procedures for the steam plant.
Explains how to test the steam temperature limiter and low water safety device.
Details the procedure to test the steam temperature limiter function.
Describes how to test the flue-gas temperature limiter function.
Explains how to activate the feed pump in emergency situations for cooling.
Guides on how to test the safety valve and steam pressure limiter functions.
Explains the procedure to test the flame monitoring system.
Provides daily and periodic maintenance instructions for the steam plant.
Details the procedure for draining the steam generator to prevent frost damage.
Explains how to preserve the steam generator for long periods of inactivity.
Lists the required preservation solutions and their preparation.
Guides on how to apply the preservation solution to the system.
Details the steps for bringing the steam generator back into operation after a standstill.
Explains how to remove boiler sediment using a special solvent.
Lists the necessary preparations before removing boiler sediment.
Details the preparation of the solvent for sediment removal.
Explains how to start and stop the boiler feed pump during sediment removal.
Describes the process of neutralizing the heating system after sediment removal.
Provides examples for setting steam pressure control and limiting parameters.
Explains how to adjust the operating pressure via the touchscreen.
Details the procedure for adjusting the steam pressure limiter by authorized personnel.
Provides instructions for replacing the heating system of the steam generator.
Explains how to clean the heating system from soot and grease.
Guides on how to adjust and measure burner settings for optimal performance.
Describes the general design and operation of the burner system.
Details the burner operation modes for oil and gas.
Explains burner operation when flue gas recirculation is active.
Provides an exploded view and repair kit information for the water pump.
Provides an exploded view and repair kit information for the water pump.
Provides an exploded view and repair kit information for the water pump.
Provides important notices regarding the water pump's operation and potential issues.
Outlines routine maintenance tasks for the water pump, including lubrication and oil changes.
Specifies the frequency and type of oil for pump lubrication.
Defines the intervals for performing an oil change on the water pump.
Describes cleaning and replacing valves for decreased pump performance.
Explains when to install new packings due to leakage or wear.
Guides on shutting off the generator and performing repairs.
Details the procedure for dismantling, cleaning, and replacing suction and pressure valves.
Explains how to replace packings and plungers for different pump models.
Provides physical dimensions and weight specifications for different steam generator models.
Lists performance data such as steam output, heat output, and consumption for various models.
Presents connection and adjustment data for steam, gas, and oil systems.
Details gas connection types, shut-off valves, and pressure regulators.
Shows oil connection types, hoses, filters, and pressure reducers.
Provides specifications for the flue gas connection, including chimney and draught requirements.
Lists exhaust gas quantities and CO2 values for different fuels and models.
Outlines the required quality and temperature for boiler feed water.
Lists the EU directives and standards the firing control automat complies with.
Highlights special features of the firing control automat like undervoltage recognition and multi-color display.
Refers to separate instructions for function and fault indications.
Explains how to display the flame signal current during burner operation.