CHALLENGER SECURITY PRODUCTS
UNIT 2 /4 ARKWRIGHT COURT
FYLDE IND ESTATE BLACKPOOL
LANCASHIRE FY4 5DR TEL 01253 792898 TECHNICAL
The Challenger "Spirit" is a high quality external combined sounder and
strobe unit. Features include a digital timed SAB with dual fail safe action, a
high efficiency Piezo sounder and an integral high intensity double lens
strobe.
Technical Description of the SPIRIT
+
This requires a constant 12V and 0V from the control panel
HOLD OFF
This "HOLDS OFF" the piezo siren in normal operation
.
-
It also allows the battery to be trickle charged
STB
-
Provides an output from the control panel to flash the strobe and is
independent
of the sounder inputs.
TRG
-
In normal operation this activates the sounder only when a Negative
Trigger is
applied by the control panel.
PIEZO
Provides the siren output to drive the piezo sounder
RTN
-
In normal operation this supplies a
permanent signal to the control panel as
part of the 24 hour tamper loop
MICRO
This is for N/C Tamper switches, which for
m part of the 24 hour tamper
SWITCH
circuit
BAT
Battery Link. After completing all connections this link must be move
d to
the ON position before fitting the bell box cover.
This enables charging of the battery and correct function of the SPIRIT.
SAB
Self activating bell ( use for primary sounder )
SCB
Self contained bell ( use for secondary sounder )
Note:
Isolate strobe before
removing
the cover ( HIGH VOLTAGE )
Question and Answer IconNeed help?

Do you have a question about the Challenger Spirit and is the answer not in the manual?

Challenger Spirit Specifications

General IconGeneral
BrandChallenger
ModelSpirit
CategoryMarine Equipment
LanguageEnglish

Summary

Challenger Spirit Technical Description

Spirit Unit Safety Warning

Warning to isolate the strobe before cover removal due to high voltage.

Product Indicators and Jumpers

Indicators

Explanation of Orange LED (HOLD OFF) and Red LED (Tamper Switch).

Jumpers Configuration

Details on Timer Select, Battery Select, and Mode Select jumpers.

Factory Presets and Specifications

Factory Presets

Default settings for Mode, LED, Timer, and Battery.

Technical Specifications

Key technical details including voltage, current, and flash rates.

Installation and Testing Guide

Installation Steps

Step-by-step instructions for mounting and wiring the unit.

Commissioning and Testing

Procedures for triggering the sounder and testing the timer function.