Do you have a question about the Champion Essick 3000 DD and is the answer not in the manual?
Brand | Champion Essick |
---|---|
Model | 3000 DD |
Category | Air Conditioner |
Language | English |
Pre-wet pads for optimal cooling by running the pump before starting the blower.
Cooler can be used without water for ventilation when outside air is cool or humidity is high.
The cooler can be set up for automatic operation using a thermostat and attic exhaust dampers.
Determine required window opening size based on the unit's CFM rating, allowing 2 sq ft per 1000 CFM.
Guides for installing optional 4-piece duct adapters, including alignment and attachment procedures.
Instructions for connecting the motor cord and mounting the blower motor securely.
Details on installing the motor pulley and aligning it with the blower drive pulley.
Warnings and guidance for electrical hook-up, emphasizing qualified electricians and conformity to standards.
Steps for installing the drain nipple and overflow pipe in the pan for water management.
Guidance on connecting the water supply using a saddle valve or sillcock, avoiding soft water.
Instructions for installing the bleed-off kit to prevent scale buildup, including restrictor clamp use.
Procedure for adjusting the drive pulley to ensure maximum air delivery without motor damage.
Measure amperage draw with pads wet and unit started, adjusting pulley if necessary.
Steps for cleaning the pump, including impeller and spout check for blockages.
Guidance on oiling blower bearings and motor annually with non-detergent oil.
Recommendation to replace pads once or twice a season for optimal performance.
Procedure to check and readjust belt tension to a 3 lb force deflecting 3/4 inches.
Ensuring the bleed-off valve is not clogged for proper operation.
Instructions to drain all water from the cooler and supply line when not in use.
Disconnecting the motor and pump when the cooler is not used for extended periods.
Suggestion to cover the unit to protect its finish during extended periods of non-use.
Diagnosing and resolving issues related to the unit not starting or delivering air.
Troubleshooting causes for reduced air flow when the cooler is running.
Identifying and fixing problems causing insufficient cooling performance.
Resolving issues where the motor repeatedly turns on and off.
Troubleshooting causes of unusual noise during operation.
Addressing sources of odors, such as stagnant water or mildewed pads.
Diagnosing and fixing water leaks or improper drainage issues.
Resolving high humidity levels caused by inadequate air exhaust.