FM-200 Gamma Series Systems
®
GENERAL INFORMATION
The Chemetron Fire Systems Gamma Series Systems are
automatic suppression systems using the FM-200 chemi-
cal agent and consisting of four basic components and
their associated accessories.
FM-200 Components
Control Panels
Detection and Alarm Devices
Completer Kits
Features
The FM-200 components consist of agent containers,
1
container supports (racks), and discharge nozzles.
The control panel is the brains of the system and is
2
used to monitor the detection and accessories.
The detection, alarm devices, and accessories are the
3
external devices that act as the eyes and voice of the
system as they give audible or visual signals.
The completer kits consist of warning signs, hoses,
4
connection fittings, pressure gauges or solenoid
valves, and the actuator required to operate the
cylinder valve.
The system and its components are agency tested for total
flooding applications and should be used in accordance
with the guidelines contained in National Fire Protection
Association 2001. A total flooding application can be de-
fined as injecting FM-200 into an enclosure or volume
having the structural integrity to retain the agent during
and after discharge. The design of such a system requires
that the FM-200 chemical agent be discharged from its
container within 10 seconds and be thoroughly mixed
throughout the protected volume, reaching a minimum
concentration level of 7%, but not exceeding 9% in
normally occupied spaces.
GAMMA SERIES SYSTEM EQUIPMENT
DESCRIPTION
The Gamma System permits higher discharge rates and is
particularly adaptable to areas requiring larger quantities
of FM-200. A description of the various equipment com-
ponents unique to the Gamma System follows.
Cylinder and Valve Assembly
Gamma Series cylinders are available in
four different capacities and are
charged with FM-200 to a filling densi-
ty up to 70 lb/ft (1121 kg/m ) of cylin-
3 3
der volume. All cylinders are super-
pressurized with dry nitrogen to a
pressure of 360 psig (2482 kPa), at
70°F (21°C). Each cylinder is equipped
with an identification nameplate indi-
cating the quantity of FM-200.
The standard cylinder assembly, hav-
ing a rigid dip tube, is designed for
mounting in a vertical position only.
The cylinder assembly is composed of
a cylinder, dip tube, and cylinder
valve.
FM-200 SPECS MENU
Question and Answer IconNeed help?

Do you have a question about the Chemetron Fire Systems FM-200 Gamma Series and is the answer not in the manual?

Chemetron Fire Systems FM-200 Gamma Series Specifications

General IconGeneral
BrandChemetron
ModelFire Systems FM-200 Gamma Series
CategoryFire Extinguisher
LanguageEnglish

Summary

General Information on FM-200 Gamma Series Systems

FM-200 System Components Overview

Details the four basic components: agent containers, control panels, detection devices, and completer kits.

FM-200 System Features

Explains the function of each system component: agent containers, control panels, detection/alarm devices, and completer kits.

Total Flooding Application Guidelines

Specifies requirements for total flooding applications, including agent discharge time and concentration levels.

FM-200 Gamma Series Cylinder and Valve Assembly

Cylinder Specifications and Charging

Describes cylinder capacities, filling density, and super-pressurization with nitrogen.

Cylinder Valve Connections

Details the six connection points on the cylinder valve, including actuators and gauges.

Cylinder Valve Operation Modes

Illustrates the cylinder valve in both standby and actuated modes.

Gamma Series System Equipment Description

System Adaptability and Discharge Rates

Highlights the Gamma System's suitability for high discharge rates and large FM-200 quantities.

Completer Kit Components

Completer Kit Contents and Purpose

Explains the requirement for completer kits and lists their included components for installation.

Solenoid Pilot Valve Assembly Details

Describes the solenoid pilot valve assembly, its function, electrical supervision, and stock numbers.

Manual-Pneumatic Actuator Description

Details the manual-pneumatic actuator, its dual purpose, and actuation mechanism.

Pneumatic Actuator Description

Explains the pneumatic actuator's function in venting cylinder pressure for valve opening.

System Ancillary Components

Bleeder Valve Function

Explains the bleeder valve's role in preventing false discharge by venting pilot line pressure.

Discharge Connection Fittings

Describes fittings used to extend the cylinder valve discharge outlet to the piping system.

Flexible Connector Specifications

Details the lengths and construction of flexible connectors used in the system.

Pressure Gauge Assembly

Explains the need for pressure gauges for visual surveillance of cylinder pressure.

Pressure Switch Functionality

Describes the pressure switch's role in system shutdown and alarm functions.

System Configurations and Nozzles

Pressure Switch Stock Numbers

Lists stock numbers for various 2 and 4 pole pressure switches.

Check Valve Application

Explains the check valve's purpose in preventing backflow in manifolded systems.

Cylinder Rack Specifications

Details cylinder rack dimensions and mounting for single/multiple cylinders.

Nozzle Types and Discharge Control

Describes 360° Radial and 180° Sidewall nozzles for FM-200 discharge.

Nozzle Specifications and FM-200 Properties

Nozzle Height Dimensions

Provides nozzle height dimensions for 360° Radial and 180° Sidewall nozzles by pipe size.

FM-200 Physical and Chemical Properties

Describes FM-200's properties, including its suppression mechanism and decomposition products.

FM-200 Safety Considerations

Outlines safety precautions for FM-200 exposure, handling, and storage.