RADIANTE 700
S
TANDARD INSTALLATION
LEGEND
Firebox Dimension
Exact Dimension
Minimum Dimension
Air Intake
Air Outlet
FIREPLACE
CONSTRUCTION STEP 1
FIREPLACE
CONSTRUCTION STEP 2
SECTION ‘A’
A
500
1110
498
630
Flue
Lintel
Firebox
Air Grille
Firerock Insulation
Hearth Fireplace base
500
1800
See note [3]
50
860
850
To ceiling height
Cutaway
showing
lintel
850
Mesh
vent
Air grilles to be
either large front
as shown, or sides
x2 (dotted).
Mesh vents
630
50
600
IMPORTANT:
NO BRICKWORK TO
BE COMMENCED
UNTIL FIREBOX IS
PLACED IN POSITION
NOTES:
[1] Air intake grilles minimum air flow area required
= 180cm
2
each side.
[2] Air outlet grilles minimum air flow area = 240cm
2
each side
and 480cm
2
if one grille is used.
[3] Hearth height dimensions optional (Refer to Technical Data
& Installation Instructions)
[4] All dimensions in millimetres.
[5] Heater can be left freestanding.
[6] Do not scale from these diagrams
[7] Air transfer kits mandatory for exempt units to comply to
AS/NZ 4012/4013:2014. Fan optional depending
on duct length. ( Refer to Technical Data & Installation
Instructions )
August 2018
Cheminees Philippe’s policy is one of continuous development. We reserve the right to change sizes and specifications without notice.
430 Johnston St., Abbotsford, Victoria 3067 Phone: 03 9417 3315
e-mail: sales@wignells.com.au www.chemphilaust.com.au
Air Transfer Kit
Ceiling
Brick Masonry
OR
50mm Skamotec 225
*
*
*
*
=
30mm air gap
t
o combustibles
when using
S
kamotec