Emergency engine start
If the smart key voltage is low or the radio frequency signal is seriously interfered, the passive start
system will not work normally; at this moment, the system provides a standby engine startup
means:
1. Flatly put the key into the bottom of rear cup holder with the key front side up, and do not
depress the brake pedal (for CVT vehicle);
2. Press the starting switch (do not depress the brake pedal etc.), and the power supply mode will
be changed to IGN, with following words indicated on the instrument: The verification is successful
and now the engine can be started”;
3. Depress the brake pedal (for CVT vehicle), and press the starting switch to start the engine.
1. Cup holder;
2. Armrest box;
3. “Standby ignition key location symbol” on
the bottom of the rear cup holder;
4. Smart key.
1 2 3 4
Front side up