A. BasicBedOperaons
B. BedExitAlarm
1. Placethepaentinthebed
2. PresstheSET/RESETbuontocyclethroughthethreesensivitylevels(zones);stopattheappropriatelevel
3. Anaudible“chirp”willsoundtoindicatethattheBedExitAlarmhasbeenarmed
4. PresstheCHIMEbuonto
cyclethethroughthevolumeandprioritycallopons;stopatthedesiredlevel
ABedExitAlarmCanBeSilencedBy:
PressingeithertheSET/RESETortheCHIMEbuon.ThiswillpausetheBedExitAlarm.ToresumeBedExitAlarm
operaon,returnthepaenttothebedandpresstheSET/RESETbuon.Ifthepaentisnot
returningtothebed,
presstheSET/RESETbuontodeacvatetheBedExitAlarm;OR
Returningthepaenttoor i ginal posioninthebed.A“chirp”willsoundtoindicatetheal a rmhasbeenre‐acvated.
ToChangeBedExitAlarmChime(Song):PUSHandHOLDtheCHIMEbuonfor3secondstojumpdirectlytothemenusecon
thatwillallowyoutocyclethroughthe differentchimes.Whenthedesiredchi meisheard,presstheON /ENTERbuontoselect.
C. UnderbedNightlight
PresstheLIGHTbuontoscrollthroughthebrightnesslevelsoftheunderbednightlight(OFF–LOW–MED–HIGH).
BedExitNightlight:Automacallyilluminateswhenthepaentexitsthebed.Automacallyturnsoffwhenthepaentre‐
entersthebedoraer15minuteshaselapsed
.
4‐70‐029‐RevE
F
A
D
C
B
BedArculaons
Usefootboardcontrolorsiderailcontrolstoraiseorlowertheheadsecon(backrest)and/orthekneeseconofthe
maressdeckortheenrebed.PUSHandHOLDtheUP/DOWNarrowbuonstoachievethedesiredarculaon.
EmergencyCPR
PUSHandHOLDtheCPRbuontoflaenthehead(backrest)andkneeseconsofthemaressdeckinanemergen cy.
Trend/
ReverseTrend
PUSHandHOLDtheTRENDorrev.TRENDbuontoachieveeitherfuncon.Tolevelthebed,pressandholdthe
oppositeTRENDfunconbuon.Thebedwillautomacallystoponcelevel.
Chair
PUSHandHOLDtheCHAIRbuonunlthebedstopsinthedesiredchairposion.PUSHandHOLDtheLEVELALL
buontoflaenthemaressdeckandtolevelthebed.
AutoContour
PresstheCONTOURbuontoengagetheAutoContourfuncon.AnilluminatedCONTOURbuonindicatesthat
theAutoContourfunconisengaged.Thekneeseconwillautomacallyraiseorlowerwhenthehead
(backrest)seconofthemaressdeckisarculated.The
AutoContourfunconwillbeignoredwhenthe knee
Lock‐Outhasbeenacvated.
LevelAll
PUSHandHOLDtheLEVELALLbuontoflaenhead(backrest)andkneeseconsofthemaressdeck.
Lock‐Outs
Torestrictpaentuseofallsiderailcontrols,pressthepaentLOCKbuonundereachfuncon.WhentheLOCK
buonisilluminated, paentuseofthatparcularfunconfromanysiderailcontrolisrestricted.Whenthe
LOCKbuonisnotilluminated,pa
entuseofthatfunconispermied.
NOTE:ThefootboardstaffcontrolremainsfunconalwhenpaentLock‐Outshavebeenacvated.
MasterLock‐Out
Torestrictallsiderailandfootboardcontrols,pressallthreeLOCKbuonssimultaneously.WhentheMaster
Lock‐Outhasbeenacvated,allthreeLOCKbuonswillflashsequenally.Tode‐acvatetheMasterLock‐Out,
pressallthreeLOCKbuonssimultaneouslyagain.
NOTE:The
EmergencyCPRfunconandNurseCallbuonsremainfunconalwhentheMasterLock‐Outhasbeenacvated.
QuickReferenceGuide
SpiritSelect™