EasyManua.ls Logo

CHICAGO 93252 - User Manual

CHICAGO 93252
11 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
SKU 93252 For technical questions, please call 1-800-444-3353 Page 1
VIBRATORY TUMBLER
93252
ASSEMBLY AND OPERATING INSTRUCTIONS
Visit our website at: http://www.harborfreight.com
Read this material before using this product.
Failure to do so can result in serious injury.
SAVE THIS MANUAL.
Copyright
©
2005 by Harbor Freight Tools
®
. All rights reserved. No portion of this manual or any artwork
contained herein may be reproduced in any shape or form without the express written consent of Harbor
Freight Tools. Diagrams within this manual may not be drawn proportionally. Due to continuing improvements,
actual product may differ slightly from the product described herein. Tools required for assembly and service
may not be included.
For technical questions or replacement parts, please call 1-800-444-3353.
Revised Manual 09j
Downloaded from https://www.rsmanuals.com
Question and Answer IconNeed help?

Do you have a question about the CHICAGO 93252 and is the answer not in the manual?

Summary

Product Title and Critical Warning

Safety First: Save This Manual

Crucial warning to read material before use to prevent injury and save the manual.

Specifications

Product Specifications Details

Details on construction, power, dimensions, and weight of the vibratory tumbler.

Safety Warnings and Precautions

General Safety Rules

Essential safety rules for operating power tools, covering work area, electrical, and operator safety.

Personal Safety

Personal Safety Guidelines

Advice on alertness, attire, and avoiding accidents during operation.

Tool Use and Care

Tool Usage and Care Recommendations

Guidance on proper tool application, maintenance, and accessory use.

Service

Service and Repair Guidelines

Guidelines for tool service, maintenance, and using identical replacement parts.

Specific Safety Rules

Specific Safety Rules and Hazards

Detailed safety rules including PPE, environment, operation, and health hazards.

GROUNDING

Grounding Requirements Explained

Explanation of grounding for three-prong plugs and double-insulated tools.

EXTENSION CORDS

Extension Cord Usage Guidelines

Recommendations for selecting and using extension cords based on gauge, length, and outdoor use.

Unpacking

Unpacking and Initial Checks

Instructions for unpacking and verifying the product's condition.

Operation

Tumbler Operation and Safety

Steps for operating the tumbler, including media loading, operation, and post-operation safety.

Maintenance

Maintenance and Upkeep

Guidance on tumbler maintenance, gasket checks, and motor protection.

Some Notes on Media

Media Usage and Selection

Information on media suitability for vibratory tumblers and recommended types.

Parts List and Disclaimer

Parts List and Repair Disclaimer

Reference to the parts list and a disclaimer regarding DIY repairs.

Warranty Information

Limited Warranty Details

Details on the product's 1-year/90-day warranty, coverage, and claims process.

Overview

This document outlines the assembly, operation, and maintenance of the CHICAGO Electric Power Tools Vibratory Tumbler, Model 93252. This tool is designed for dry polishing applications and is particularly effective for various finishing tasks, including rust removal, deburring, polishing, and cleaning small parts.

Function Description

The Vibratory Tumbler operates by using a vibrating action to process items within a drum filled with polishing media. This process is ideal for achieving a smooth finish, removing surface imperfections, and cleaning a variety of materials. Unlike wet tumblers, this device is specifically designed for dry media, making it suitable for tasks where water-based processing is not desired or appropriate. The tumbler's design allows for efficient processing of small and hard-to-reach parts, making it a versatile tool for hobbyists and professionals alike. The vibratory action ensures that the media consistently interacts with the items, leading to uniform results. The device is equipped with a power switch for easy operation and a secure lid mechanism to contain the contents during use.

Usage Features

Before operating the tumbler, it is crucial to read and understand all safety warnings and precautions outlined in the manual. The work area should be kept clean, well-lit, and free of obstructions to prevent accidents. Always wear ANSI approved safety impact eye goggles, a full face shield, and heavy work gloves to protect against potential hazards. The tumbler should only be used on a solid, level surface to ensure stability during operation.

To begin, fill the tumbler bowl approximately two-thirds full with the chosen polishing media. The manual recommends various types of dry media, such as plastic beads, ground corn cobs, and walnut shells, which are available from Harbor Freight Tools. It is important to note that ceramic or other very hard media should not be used in this tumbler, as they can cause excessive wear on the bowl. Metal parts can be added to the bowl, up to a maximum of 5 pounds of total material (including media). Overfilling should be avoided, as it can slow down the polishing process. If the tumbler runs too slowly, some items should be removed. Conversely, not having enough media can damage parts.

Once the media and parts are loaded, place the cover on the tumbler bowl, ensuring the gasket is correctly seated. Secure the cover firmly with the washer and wing nut. Then, press the power switch to the "ON" position.

The type of media and tumbling time will vary depending on the desired outcome:

  • For degreasing: Use ground corncob, walnut shell, or plastic media. Tumble for 30 minutes to 1 hour.
  • To remove rust: Use commercially available treated plastic media. Depending on the condition of the materials, tumbling may take 2 to 6 hours.
  • To polish: Tumble in walnut hull or corncob media. Do not add water. A small amount of commercial metal polish can be added for enhanced results.

A critical safety precaution is to allow dust to settle before opening the tumbler after use. Tumbling often creates dust that can be harmful if inhaled. Therefore, it is recommended to wait at least one hour after turning off the tumbler before opening it. Never operate the tumbler with the top off, as this can create hazardous dust and may eject media or work materials.

After the tumbling process is complete, move the power switch to the "OFF" position before opening the tumbler and retrieving the processed items.

Maintenance Features

Proper maintenance is essential to ensure the longevity and safe operation of the Vibratory Tumbler.

  • Gasket Inspection: Regularly inspect the gasket that seals the tumbler bowl. If it becomes damaged or worn, it should be replaced immediately to maintain a proper seal and prevent dust leakage.
  • Rubber Feet: The rubber feet located at the bottom of the bowl can wear out over time with extensive use. Periodically check their condition and replace them if they show signs of wear.
  • Motor Protection: The motor is a crucial component and must be protected from water and moisture. Always store the tumbler in a dry location when not in use to prevent electrical damage.
  • Media Considerations: This tumbler is specifically designed for dry polishing media and is not suitable for wet or water-based media. It is also not intended for polishing stones, which typically require lapidary tumblers that use water-mixed media. Using inappropriate media, especially very hard materials like ceramic, can cause premature wear to the tumbler bowl. The manual provides a chart of recommended dry media types, including plastic beads with various abrasives, walnut shells, and corn cob, along with their applications and densities. Experimentation with different media types is encouraged to achieve desired results.
  • General Tool Care: Keep the tool clean and free from debris. Avoid abusing the power cord; never carry the tool by the cord or pull the plug from an outlet by the cord. Keep the power cord away from heat, oil, sharp edges, and moving parts. Replace damaged power cords immediately to prevent electric shock.
  • Professional Service: Any tool service, especially repairs, should be performed by qualified repair personnel using identical replacement parts. Unauthorized repairs or the use of non-identical parts can create a risk of electric shock or injury.
  • Storage: Store idle tools out of reach of children and other untrained persons to prevent accidental use.

By adhering to these usage and maintenance guidelines, users can ensure the safe and effective operation of their Vibratory Tumbler for a wide range of dry polishing and finishing tasks.

CHICAGO 93252 Specifications

General IconGeneral
Model93252
CategoryUltrasonic Jewelry Cleaner
BrandCHICAGO
Ultrasonic Frequency42, 000 Hz
Power35 W
MaterialPlastic
Capacity20 oz