16
TECHNICAL FEATURES
Mod. UM550
Nominal characteristics AC/DC Mains
Adaptor: 100-240 V
˜
50/60Hz 0.5A Output:
12V
1200 mA
Nominal voltage humidifier power supply: 12
V
Absorbed power: 15W
Ǡ ƿ ǀ
ǂȜȝțȜȝțț
Ultra-sound transducer frequency: 2.45 MHz
Water tank capacity: 0.79 L approx. / 0.43 L
useful
Nebulising capacity: 38 ml/h, approx.
ƿ
30m³ .
Autonomy: 6 hours, approximately
ƿȟț
ƿ
ƿ
Weight: 0.4 kg .
ƿȜȝțȜȝțȜȝț
țțțțțȞȣȡțțțțțț
Storage environmental conditions:
ƿǂȟțʕʑȢțʞ
ƿȜțʏʕȤțʏ
Declaration of EC Compliance:
ǀǀ-
difier, model UM550, is in compliance with the
essential requirements and other provisions
   ȝțțȟǠȜțȣǠ ǩ-
tromagnetic compatibility) and 2006/95/
ǩǪǀ
ǀǀǀǀȜ
– 22070 Grandate (Co) Italy for a copy of this
ǀ
SYMBOLS KEY
double insulation
-
sential requirements laid down in the

DŽ
user instructions
please read the instructions booklet
for indoor use only
TROUBLE SHOOTING
Problem Solution
If the humidifier does not work Check that the AC/DC main adaptor (7) cable plug is cor-
rectly connected to the mains adaptor connecter (3) and
that the e AC/DC mains adaptor (7) is plugged into the
mains socket
Check that the ON/OFF switch (2) is in the ON (I) position.
Check there is enough water in the tank (not below the mi-
nimum level mark)
Of the appliance on/off indicator
ǩȜǪ-
pels air and not nebulised water
Check there is no scale residue on the water level sensor or
on the transducer.
Check there is enough water in the tank (not below the mi-
nimum level mark)
Clean the appliance following the instructions provided.
Air the water tank (5) in a cool place for 12 hours.