Inverter heat pump solution
Connect Wi-Fi on mobile phone and input password, and then control equipment by Wi-Fi. When
APP connects Wi-Fi successfully,“ ” lights on.
h. Running Status Checking
1. Press “ ” for 5 seconds, it will enter running status checking.
2. During this time, the display will show the status symbol “C0” and its corresponding value.
3. Change status through “ ” and “ ”, the corresponding value also changes.
4. Press “ ” to quit “Running Status Checking” mode
5. Running status checking table:
Evaporator coil pipe temp
F. Testing
1. Inspect heat pump before use
a. The ventilating device and outlets are operating adequately and are not obstructed.
b. It’s prohibited to install refrigeration pipe or components in corrosive environment.
c. Inspect the electric wiring on basis of the electric wiring diagram and earthing connection.
d. Double confirm the main machine power switch should be off.
e. Inspect the air inlet and outlet.
2. Leakage detection notice and method
a. Leakage checking is prohibited in closed area.
b. The ignition source is prohibited during the leakage inspection. A halide torch (or any
other detector using a naked flame) shall not be used.
c. Leakage detection fluids can be applied with most refrigerants but the use of detergents