Operating Instructions for ZHRV5 Series Relay
3-phase voltage monitoring relay
Function Features
Controls its own supply voltage(True RMS measurement).
Set 8-level rated operating voltage through knob.
Measuring frequency range:45Hz~65Hz.
Voltage measurement accuracy <1%.
Control status is indicated by a LED.
The relays are designed for clip-on mounting on rail.
Applications
Control for connection of moving equipment (site equipment,agricultural
equipment, refrigerated trucks).
Model and Connotation
ZHRV5
Rated control supply voltage codes:
Function code(see Table 1)
ZHRV5 series relay
-1-
Table1
Function
code
Phase
failure
Phase
sequence
Over-
voltage
Under-
voltage
Asymmetry
Delay
time
The relay is only 18mm wide.
Control for protection of persons and equipment against the consequences
of reverse running.
Normal/emergency power supply switching.
Protection against the risk of a driving load (phase failure).
Rated supply voltage
Technical Parameters
220...460V AC 3phases
Supply voltage limits
Control ciruit frequency
50/60Hz +/-10%
220-230-240-380-400-415-440-460V(P-P)
Threshold adjustment
voltage
Adjustment of asymmetry
threshold
2%...20%of Un selected
5%...15%
500ms time delay
Time delay
Hysteresis
Adjustable 0.1s...10s,10%
2%
176...552V AC
Measurement error
Reset delay
<1%over the whole range with voltage variation
1000ms
Konb setting accuracy
Phase failure sensitivity
1%of scale value
0.7Un
Conventional heat current
Rated insulation voltage
Voltage detection threshold
IP degree of protection
460V
<165V
IP20
Height above sea level
Operation temperature
Relative humidity
Storage temperature
Mechanical durability
1000000 cycles
<=2000m
-5...40
-25...75
<=50%(40)
Utilisation category
Contact capacity
AC-15
Ue/Ie:250V/1.5A
Voltage range
Output type
Power consumption
Tightening torques
Connecting capacity
Mounting support
1 C/O
0.5mm ~2.5mm
0.5Nm
<=1.2VA
35mm symmetrical DIN rail conforming to
EN/IEC 60715
Panel Diagram
2
1
3
4
5
6
Relay output and time delay LED.R/T
Function LED.F1
Function LED.F2
Asymmetry rate adjust knob.Asy
Time delay adjust knob.Tt
Rated voltage range selection knob.
7
8
Overvoltage setting knob.U>
Undevoltage setting knob.U<
5A
M460:220-230-240-380-400-415-440-460VAC
Pollution degree
3
Electrical durability
100000 cycles
R
03
04
05
06
07
08
09
10
11
12
2%...20%
2%...20%
2%...20%
2%...20%
2%...20%
15%
-20%...2%
-20%...2%
-20%...2%
-20%...2%
-20%...2%
-15%
5%...15%
5%...15%
8%
8%
8%
0.1s...10s
0.1s...10s
0.1s...10s
0.1s...10s
0.1s...10s
0.1s...10s
2s
2s
2s
/
Note:the function is available
Run up delay at power up
Measuring range
176...552V
1
ZHRV5-03
2
3
4
5
6
1
ZHRV5-04
2
3
4
7
1
ZHRV5-05
ZHRV5-06
ZHRV5-07
ZHRV5-08
ZHRV5-09
ZHRV5-10
ZHRV5-11
ZHRV5-12
2
3
4
7
6
1
2
3
4
8
6
1
2
3
4
1
2
3
4
7
1
R/T
ZHRV5-03
R
R/T
ZHRV5-1
F1
F2
Un
230
460V
440
415
400
380
240
220
R
Tt
R/T
5
Asy
15%
0.1
2
4
6
8
10s
ZHRV5-04
F1
F2
Un
230
460V
440
415
400
380
240
220
8
10
12
R
Tt
2
U>
0.1
2
4
6
ZHRV5-05
Un
230
415
400
380
240
220
8
10
12
4
6
14
16
R/T
20%
8
10s
F1
F2
460V
440
18
R
Tt
R/T
-2
U<
-20%
0.1
2
4
6
8
10s
ZHRV5-06
F1
F2
Un
230
460V
440
415
400
380
240
220
-8
-10
-12
-4
-6
-14
-16
-18
R
Tt
0.1
2
4
ZHRV5-0
Un
230
400
380
240
220
2
U>
8
10
12
4
6
-2
U<
-8
-10
-12
-4
-6
R/T
6
8
10s
F1
F2
460V
440
415
20%
14
16
18
-20%
-14
-16
-18
R
Asy
R/T
F1
F2
Un
230
460V
440
415
400
380
240
220
2
U>
20%
8
10
12
4
6
14
16
18
-2
U<
-20%
-8
-10
-12
-4
-6
-14
-16
-18
5
15%
8
10
12
R
ZHRV5-10
8 8
6
5
2
2
Conform to:IEC60 9 47 -5 -1 standard
Question and Answer IconNeed help?

Do you have a question about the Chtce ZHRV5 Series and is the answer not in the manual?

Summary

Function Features

Applications

Model and Connotation

Panel Diagram Controls

Relay Output and Time Delay LED

Indicates relay status and time delay operation.

Rated Voltage Range Selection Knob

Selects the operating voltage range for the relay.

Function LED F1

Indicator LED for function F1 status.

Function LED F2

Indicator LED for function F2 status.

Asymmetry Rate Adjustment Knob

Adjusts the asymmetry threshold setting.

Time Delay Adjustment Knob

Adjusts the time delay setting for tripping.

Overvoltage Setting Knob

Sets the overvoltage detection threshold.

Undervoltage Setting Knob

Sets the undervoltage detection threshold.

Technical Parameters

Function Diagram and LED Descriptions

LED Functions Table

Details the meaning of R/T, F1, and F2 LEDs for different functions.

Phase Failure and Phase Sequence Diagram

Illustrates relay behavior during phase failure and sequence errors.

Overvoltage and Undervoltage Diagram

Shows relay response to over and undervoltage conditions.

Asymmetry Function Diagram

Depicts the relay's operation based on asymmetry thresholds.

Operating Instructions

Setting Controls

Guide on setting voltage range, thresholds, and time delay.

Relay Behavior

Explanation of relay disconnection on voltage failure and open phase.

Phase Sequence Detection

How the relay detects correct phase sequence and failures.

Overall Dimensions

Wiring Diagram

Important Warnings

Installation and Maintenance

Instructions for professional installation, operation, and repair.

Wiring Precautions

Guidelines for wiring to prevent interference and ensure safety.

Environmental and Usage Restrictions

Conditions to avoid: dust, corrosive gases, direct sunlight, explosion hazards.

Product Warranty

Information on the product's warranty period.

Chtce ZHRV5 Series Specifications

General IconGeneral
BrandChtce
ModelZHRV5 Series
CategoryRelays
LanguageEnglish