The maximum runtime for stage 1 before stage 2 is activated to achieve the temperature
setpoint.
2- Minimum Off Time:
The minimum OFF time of the heating or cooling system before the thermostat turns it ON
again. (A minimum value of 5 minutes is recommended to prevent the system from short
cycling.
3- Minimum On Time:
The minimum ON time of the heating or cooling system before the thermostat turns it OFF
again. (A minimum value of 5 minutes is recommended to prevent the system from short
cycling.
4- Heating Dissipation Time:
Time for which the fan of your HVAC system will run after the heating has been turned off.
This ensures that the hot air left in the ducts is blown into the room to maximize the use of
generated heat.
5- Cooling Dissipation Time:
Time for which the fan of your HVAC system will run after the cooling has been turned off.
This ensures that any remaining cool air in the ducts is circulated into the room to maximize
the efficiency of the cooling cycle.