Chapter 15 Performance Monitoring
15.4.1 E1-N-14 Card and E1-42 Card Performance Monitoring Parameters
Figure 15-1 Monitored Signal Types for the E1-N-14 Card and E1-42 Card
Figure 15-2 shows where overhead bytes detected on the application-specific integrated circuits (ASICs)
produce performance monitoring parameters for the E1-N-14 card.
Note The E1-42 card uses the same PM read points. The only difference from the Figure 15-2 is that the
number of ports on the E1-42 equal 42.
Figure 15-2 PM Read Points on the E1-N-14 Card
The PM parameters for the E1-N-14 card and E1-42 card are described in Table 15-2 on page 15-5
through Table 15-4 on page 15-6.
71101
ONS 15454
SDH
E1 STM16
Fiber
Near End
E1 Signal
CRC4 Framing Path PMs Near + Far End Supported
ONS 15454
SDH
E1STM16
Far End
E1 Signal
VC-12 Low-Order Path PMs Near End Supported
71100
ONS 15454 SDH
E1 Card
LIU
Framer
BTC
Tx/Rx
Cross-Connect
Card STM-N
CV-L
ES-L
SES-L
Rx P-EB
Rx P-BBE
Rx P-ES
Rx P-SES
Rx P-UAS
Rx P-ESR
Rx P-SESR
Rx P-BBER
Tx P-EB
Tx P-BBE
Tx P-ES
Tx P-SES
Tx P-UAS
Tx P-ESR
Tx P-SESR
Tx P-BBER
E1 Side
Low-
Order
Path
Level
SDH Side
LP-EB
LP-BBE
LP-ES
LP-SES
LP-UAS
LP-ESR
LP-SESR
LP-BBER
PMs read on Framer
PMs read on LIU