1-7
Catalyst 6500 Series Supervisor Engine Guide
OL-7397-03
Chapter 1      Catalyst 6500 Series Switch Chassis Overview
  Catalyst 6509-E
  • Supervisor Engine 32 and Supervisor Engine 32 PISA do not support the Switch Fabric Modules 
(WS-C6500-SFM and WS-X6500-SFM2). The Switch Fabric Modules and Supervisor Engine
 32 or 
Supervisor Engine
 32 PISA cannot be installed in the same chassis.
  • The uplink ports are fully functional on all redundant supervisor engine models when they are in 
standby mode.
Note In systems with redundant supervisor engines, both supervisor engines must be the same model 
and have the same daughter card configurations. Each supervisor engine must have the resources 
to run the switch on its own, which means all supervisor engine resources are duplicated. 
Identical supervisor engine memory configurations are recommended but are not required as 
long as the supervisor engine with the smaller memory configuration is sufficient to run the 
configured features of the switch. Additionally, each supervisor engine must have its own flash 
device and console port connections.
Additional information on the Catalyst 6509 switch chassis including data sheets and chassis installation 
is located at:
http://www.cisco.com/en/US/products/hw/switches/ps708/tsd_products_support_series_home.html
Catalyst 6509-E
The Catalyst 6509-E switch is an enhanced version of the Catalyst 6509 switch. The 9-slot (numbered 
from (1) top to (9) bottom), 15
 RU, horizontal chassis supports redundant power supplies and redundant 
supervisor engines. It also supports a greater power capacity per slot than the Catalyst
 6509 switch 
chassis and supports the WS-X67xx and WS-X68xx switching modules. Supervisor engine support and 
restrictions for the Catalyst
 6509-E includes:
  • Supervisor Engine 2, Supervisor Engine 32, Supervisor Engine 32 PISA, Supervisor Engine 720, 
Supervisor Engine
 720-10GE, and Supervisor Engine 2T are supported. 
Note Refer to your software release notes for specific information on the minimum software release 
versions required to support the supervisor engines in the Catalyst
 6509-E chassis.
  • Supervisor Engine 2 must be installed in slot 1 or slot 2.
  • Supervisor Engine 32, Supervisor Engine 32 PISA, Supervisor Engine 720, Supervisor 
Engine
 720-10GE, and Supervisor Engine 2T must be installed in slot 5 or slot 6.
Note Slots not occupied by supervisor engines can be used for modules. Check your software release 
notes for any restrictions on the type of module that can be installed.
  • Supervisor Engine 720, Supervisor Engine 720-10GE, and Supervisor Engine 2T have a built-in 
switching fabric. Switch Fabric Modules (WS-C6500-SFM and WS-X6500-SFM2) are not 
supported by Supervisor Engine
 720, Supervisor Engine 720-10GE, and Supervisor Engine 2T and 
cannot be installed in the same chassis.