17
5.
Disassembly and transport
5.1.
Disassembly
Stop the generator (
par. 6.5.
);
wait for depressurization (about a minute);
switch off the generator (
par. 6.6.
);
disconnect the electric power cable;
close all valves (air inlet, tanks, nitrogen) and detach the pneumatic
connections;
unscrew the feet using the allen key 4 mm until the generator is free to move;
unscrew the screws that block the stabilizers to the generator, put this
component in a bag and attached it to the generator.
m
After removal the stabilizers pay attention to the handling of the ge-
nerator, THE GENERATOR IS UNSTABLE.
5.2.
Transport
e
Remember that during transport the generator must always remain in a vertical
position.
If conserved, use the original packaging; otherwise use a pallet of adequate di-
mensions to hold the generator, affixing instructions in visible locations, such as:
THIS WAY UP, KEEP IT IN VERTICAL POSITION.
Lift the generator with the eyebolts in dotation.