EasyManua.ls Logo

Clas Ohlson CB5-5L-BS - Product Description; Functions; Re-setting; <14 Ah - Charge Setting 1

Clas Ohlson CB5-5L-BS
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4
English
2. Product description
• Automatic battery charger for 12 V lead batteries.
• Intended for use with lead batteries (WET, GEL, AGM etc.) with a capacity of
1.2Ah to 120 Ah.
• Protection against spark emissions and short circuiting.
• LED indicates charging status and incorrect connection.
• Protection against damp and dust - IP65.
• Charging at 0.8/4 A.
• Switches automatically to maintenance charging when the battery is fully charged.
3. Functions
A. Re-setting
When the charger is connected to an electric socket it is automatically reset and
charging does not commence until you have started the charger manually.
B. <14Ah – Charge setting 1
Suitable for motorcycle batteries and other smaller batteries (14.4 V/0.8 A).
Setting 1 is to be used for batteries with a lower capacity than 14Ah. Connect the
charging clamps to the battery (red to + and black to -), then press [MODE] to select
the desired function and start charging.
• <14Ah flashes. If you do not press any button CHARGE will light up and charging
will commence at 0.8 A (+/-10 %).
• If everything is OK CHARGE will light up during the entire charging cycle until the
voltage reaches 14.4 V (+/-0.25 V).
• When charging is complete CHARGE will switch off and FULL will be lit.
Charging will switch to conservation charging.
C. >14Ah – Charge setting 2
Suitable for car batteries, regular batteries etc. (14.4 V/4A).
Setting 2 is to be used for batteries with a higher capacity than 14Ah. Connect the
charging clamps to the battery (red to + and black to -), then press [MODE] to select
the desired function and start charging.
• >14Ah flashes. If you do not press [MODE] again CHARGE will light up and
charging will commence at 4A (+/-10 %).
• If everything is OK CHARGE will light up during the entire charging cycle until the
voltage reaches 14.4 V (+/-0.25 V).
• When charging is complete CHARGE will switch off and FULL will be lit.
Charging will switch to maintenance charging.