Network Tester
Art.no 38-3970 Model TCT-108
Please read theentire instruction manual before use and save it for future reference. Wereserve theright
for any errors in text or images and for making any necessary technical changes to this document. Ifyou
should have any questions concerning technical problems please contact our Customer Services.
Product description
• Detachable “Remote” unit for measuring at both ends of thecable.
• Indicates whether thecable is complete, broken or short-circuited.
• Indicates whether thecable is straight or crossed.
• Requires no special battery, operates on a9 V alkaline battery.
• Connections for both TP cable (RJ45) and ISDN cable (RJ11).
Operation
Inspecting TP cable (RJ45) and ISDN cable (RJ11)
Note: Never connect thenetwork tester to anetwork which is in use and is active, disconnect thecables
before testing them.
1. Connect one end of thecable to theMaster unit and theother end to theRemote unit.
DetachtheRemote unit and connect it to theother end of thecable if thecable is already installed.
2. Turn theon/off switch to ON (or S for slow testing)
3. Read theLEDs on theMaster Unit.
4. The LEDs (1–8 and G) will flash in pairs on both units simultaneously.
• If thecable is OK theMaster and Remote will flash in unison: 1 - 1, 2 - 2, 3 - 3, etc.
• If thecable is defective no LEDs will be lit.
• If “G” flashes during testing, thecable is shielded.
• If theconnected cable is crossed, Master and Remote will start flashing out of sync:
1 - 3, 2 - 4, 3 - 1, etc.
Note:
• ISDN cable (RJ11) has 6 wire cores (1–6).
• TP cable (RJ45) has 8 cores (unshielded cable) or 8 cores + shield (G).
• The on/off switch has 3 positions: “OFF”, “ON” and “S” (slow testing).
Disposal
When it is time to dispose of this product, do so in accordance with local regulations.
Ifyou are unsure how to proceed, contact your local authority.

Questions and Answers: