2-YEAR WARRANTY
www.CLIMATOUCH.com
INSTRUCTION MANUAL
Climatouch
CT0-7TC-32H
3 Heating and 2 Cooling with Humidistat
Question and Answer IconNeed help?

Do you have a question about the Climatouch CT0-7TC-32H and is the answer not in the manual?

Climatouch CT0-7TC-32H Specifications

General IconGeneral
CategoryThermostat
ModelCT0-7TC-32H
DisplayTouchscreen
Power Source24 VAC
Wi-FiYes
Programmable7-day programmable
Humidity ControlYes
BacklightYes
Remote AccessYes, via app

Summary

Outdoor Wireless Temperature Transmitter and Receiver Kit

Glossary of Terms

Selecting a Location

Mounting Climatouch™ to the Wall

Wiring Legend

Wiring Diagrams

Home Screen

Control Screen

Thermostat Operation Modes

Temperature Control Modes

Humidify and Humidity Setpoint

De-Humidify and Humidity Setpoint

Fan Operation Modes

Menu Screen

Date and Time Settings

Program Settings

Energy Watch

Set Screen Options

Vacation Mode

Filter Monitor

Advanced Settings - Features Settings

Daylight Time Configuration

Configure daylight saving time settings.

Filter Run Time Entry

Input air filter run time for filter change alerts.

Energy Watch Data Input

Enter HVAC consumption and cost for energy tracking.

Security and PIN Setup

Protect thermostat access with PIN and lock modes.

Installer Message Customization

Set custom messages to display at programmable intervals.

Temperature Unit Preference

Select display units for temperature: Celsius or Fahrenheit.

Advanced Settings - System Configuration

HVAC System Equipment Selection

Choose the type of heating and cooling equipment installed.

Cycle Rate Adjustment

Set maximum compressor cycles per hour for optimal performance.

Auto Change Threshold Setting

Define minimum temperature difference for Auto Mode changes.

Advanced Settings - Differential Settings

1st Stage Temperature Differential

Set temp difference before 1st stage heating/cooling initiation.

2nd Stage Temperature Differential

Set temp difference between 1st and 2nd stage operation.

3rd Stage Temperature Differential

Set temp difference between 2nd and 3rd stage operation.

OB Valve Energized Configuration

Reverse Heat Pump OB Valve contact for HEAT or COOL.

Advanced Settings - Timer Feature

Stage 1 Run Duration Setting

Specify minutes Stage 1 runs before Stage 2 activates.

Advanced Settings - Heat Pump

Heat Pump Operation with Furnace

Configure Heat Pump status when furnace is active.

Advanced Settings - Humidity Settings

Humidifier Fan Control

Control humidifier fan for steam or drum humidifiers.

Dehumidifier Fan Control

Manage dehumidifier fan for separate equipment or AC use.

DH Reverse Functionality

Configure DH relay for variable speed fan (open/closed).

DH Compressor Control Logic

Link dehumidifier setpoint to compressor and AC operation.

Advanced Settings - Calibration

Temperature Calibration Adjustment

Adjust temperature readings based on thermometer comparison.

Humidity Calibration Adjustment

Adjust humidity readings based on hygrometer comparison.

Simple Thermostat Mode

Enabling Simple Thermostat Mode

Convert to non-programmable mode via reset button.

Simple Mode Operation Overview

Understand simplified operation temperature and fan modes.

Troubleshooting

Touchscreen Responsiveness Issues

Troubleshoot unresponsive buttons using reset procedure.

HVAC System Operation Errors

Diagnose issues with AC, heating, or blank screen.

Lock Feature Problems

Resolve issues with partial or full lock modes.

PIN and Access Lockouts

Reset forgotten PIN to regain thermostat access.

Important Notice

Common Wire Requirement for Furnaces

Understand common wire (C) necessity for gas furnace operation.

Operation Without Common Wire

Solutions for systems lacking a common wire.

Heat Pump and Furnace Interplay

Verify operation when Heat Pump and Furnace run concurrently.

Dual Transformer Wiring Guidance

Use two transformers and circuit board traces.

Warranty

Hardware and Software Warranty

Two-year coverage for defects in materials, workmanship, and software.

Warranty Exclusions and Limitations

Conditions like physical damage or misuse are not covered.

Obtaining Warranty Service Procedures

Steps to contact and return products for repair.

Physical Dimensions

Electrical Rating

Patents

Related product manuals