Do you have a question about the CLIMAVENETA W3000 compact and is the answer not in the manual?
Display | LCD |
---|---|
Communication Protocols | Modbus |
Alarm Management | Yes |
Remote Monitoring | Yes |
Power Supply | 400V, 3-phase, 50Hz |
Refrigerant | R410A |
Sound Power Level | 65 dB(A) |
Dimensions (HxWxD) | 1200x800x600 mm |
Control Type | Microprocessor-based electronic control |
Overview of W3000 and W3000 compact user interfaces and their corresponding keys.
Details the LED indicators for compressor status, mode, and faults on the W3000 interface.
Step-by-step instructions for selecting and installing a language file on the unit.
Explains common faults that may occur if language files are omitted during the selection process.
Graphical representation of the navigation paths within the W3000 unit's menu system.
Brief descriptions of the main menu sections like Unit, Setpoint, I/O, and Clock.
Explains the clock menu functions, time band configuration, and provides an example of setting time bands.
Details methods for switching the unit on and off via keypad, parameter, digital input, time bands, and protocol.
Details methods to set the operating mode via parameter, digital inputs, or supervision protocol.
Lists and explains symbols used in the W3000 and W3000 compact user interface masks.
Details symbols available on individual machine configurations like Chiller, Heat pump, and All-in-one.
Lists heat adjustment methods available for different compressor types (Hermetic, Alternative, Screw, Centrifuge).
Illustrates proportional step adjustment on the inlet probe for chiller and heat pump modes with examples.
Explains the combined proportional and integral adjustment method, including the integral error calculation.
Describes the QUICK MIND self-adapting algorithm for adjusting water temperature and its operational model.
Explains the modulating adjustment performed on the outlet probe for Bitzer screw compressors.
Details the proportional step adjuster on the inlet probe, controlling compressor steps based on temperature.
Describes the neutral zone step adjuster on the outlet probe for compressor step control.
Explains the DIP adjuster on the outlet probe for fine-tuning compressor revs based on outlet temperature.
Procedures for accessing the alarm menu, viewing messages, and resetting active alarms.
Detailed list of alarm codes, their descriptions, causes, and reset procedures.
Details masks for the main display, temperature readings, freecooling, user access, and unit system information.
Explains masks for time bands, serial line settings, digital inputs, and accessing the alarm log.
Details masks for clock configuration, time band status, and daily/weekly time band programming.
Lists masks for setting up Type A daily time bands, including off/adj parameters.
Details masks for setting up Type B and Type C daily time bands, including off/adj parameters.
Lists masks for setting up Type D daily time bands, including off/adj parameters.
Describes masks for managing digital/analogue inputs/outputs and configurations of expansion boards.
Details analogue inputs and digital/analogue outputs for expansions 2, 3, 4, and 5.
Covers masks for slave configurations and digital/analogue I/O for slave expansions 1 and 2.
Details I/O status for slave expansions 2, 3, 4, and 5, including analogue inputs.
Covers masks for setting the unit type, operating mode, active setpoints, and accessing unit information.
Details masks showing temperatures, pressures, operating modes, and defrosting parameters for various circuits.
Explains masks for defrost status, compressor temperatures, ventilation adjustments, analogue outputs, and pump/compressor hour counters.
Covers masks showing compressor operating status, electronic thermostat valve driver status, and inverter command/speed.
Details masks for inverter status, enabling circuits/compressors, and displaying software/hardware information.