go green pay less no mess
INSTALLATION CERTIFICATION (FOR OWNER’S RECORDS ONLY)
To validate your warranty this check list should be completed by an authorized representative of Clivus
Multrum Australia. lt should be returned to Head Office at the address below only when making a
claim:
PO BOX 5467 BRENDALE QLD 4500
1. Tank enclosure - access space for maintenance provided.
2. Tank enclosure - 60 square cm opening provided to allow air to enter the tank enclosure or alternative air
source attached directly to the tank end-product compartment.
3. Tank support - entire bottom of tank supported by durable materials capable of supporting 2,000kgs/
m2, having a smooth surface. Sloping rear of tank supported {where applicable).
4. Front baffle - if not factory installed, bolted into place and sealed to the tank.
5. Air ducts - installed open side down between front baffle and rear of tank.
6. Rear baffle - installed.
7. End product drain - installed liquid to be drained by gravity.
8. No end product drain - hand or electric pump installed and operable.
9. Liquid end product - connected to subsurface disposal or storage.
10. Tank loaded with organic matter - thoroughly moistened woodshavings or other starter bed (please
specify: )
spread evenly in the tank bottom covering the’forward part of the air ducts and extending up behind the
front baffle; compost starter added.
11. Chute and Vent holes in Tank - in accordance with lnstallation Manual.
12. Chute and Vent Pipe - adequately support and no weight carried by tank shell.
13. Chute and Vent sections - jointed together and secured.
14. Toilet pedestal - fastened to floor and sealant applied.
15. Urinal (if applicable) - installed with piping sloping continuously toward tank, entering tank at rear of
toilet chute, connected with sealant.
16. Power for fan - AC provided or photovoltaic system installed.
17. Fan - installed in vent in location convenient for access. Adequate draft occurring.
18. Vent to extend minimum 600mm above roof.
19. Flashing and rain cover - installed on exterior vent.
20. User plaque - attached in toilet room.
21. “Please keep lid closed” signs attached to inside of toilet seat lid.
22. Name of person responsible for maintenance:
23. Tank Serial#
I certify that the above named Clivus Multrum installation has been inspected by me and
conforms to all specifications, instructions for installation and recommendations as oulined
Clivus lnstallation Manual, except where I have noted and given sufficient reason.
Date lnstalled by:
Signature of Clivus Agent/Distributor:
PAGE 17