CMI/MPH INTOXILYZER 5000 User Manual

Default Icon
114 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
.--
....
-
J-
INTOXllVZER',@
5000
Alcohol Breath Analysis Instrument
Operator's Manual
1ZlllIIIUIPHI
subsidiaries
of
MPD
Inc.
316
East Ninth Street, Owensboro, KY 42301
(502) 685-6200
or
1-BOO.a35-0690
o November 1989
by
CMI/MPH
No part ofthisworkcovered
by
the copyrights hereon may
be
reproduced
or copied in
any
form
or
by any means - graphic. electronic. mechanical,
including photocopying, taping or information storage and retrieval
systems'
without written permission
of
CMI/MPH.
Question and Answer IconNeed help?

Do you have a question about the CMI/MPH INTOXILYZER 5000 and is the answer not in the manual?

CMI/MPH INTOXILYZER 5000 Specifications

General IconGeneral
Sample TypeBreath
Measurement Range0.000 to 0.400 % BAC
Measurement PrincipleInfrared Spectroscopy
Operating Temperature10°C to 40°C (50°F to 104°F)
Power Supply50/60Hz

Summary

GENERAL INFORMATION

FUNCTIONAL DIAGRAMS

HARDWARE, CONTROLS, AND DISPLAYS

Digital Display

Alphanumeric display for operations, alerts, and results.

Mode Selection Switches

Switches to select modes, set time/date, perform diagnostics.

INSTALLATION

SETUP

DISPLAY MESSAGES AND COMMANDS

"UNSTABLE REF"

Microprocessor failed to get stable reference.

"PLEASE BLOW/R INTO MOUTHPIECE..."

Requesting subject to blow until tone stops.

TONES

Low-high Tone

Intermittent tone for malfunctions or errors.

Mode Sequences

5000R OPTION (five mode)

Mode sequences for the five-mode option.

5000 SERIES OPTION (four mode)

Mode sequences for the four-mode option.

Setting The Mode Selection Switches

Special Options

S6: Sample Capture Option

Enables attachment/detachment of collector device.

Other Functions

S10: Set Time

Enables setting the displayed time.

S11: Set Date

Enables setting the displayed date.

Diagnostic Tests

S1: Display Test

Scrolls all displayable characters.

Print Test

Prints characters and transistor numbers for malfunction diagnosis.

Switch Priorities And Invalid Mode

OPERATING PROCEDURE

Typical ABA Test

Step-by-step guide for ABA test sequence.

9. "PLEASE BLOW .###"

Displaying subject's alcohol concentration.

PRINTED OUTPUT AND EVIDENCE CARD FORMATS

Failed Diagnostic Check Evidence Card Format

Example of evidence card for failed checks.

CONTROL CHECK

Performing Control Check in ACA Mode

Steps for control check within ACA sequence.

THE SAMPLE CAPTURE OPTION

Instructions for Using the Collector Tube and the Toxtrap Holder

Diagrams and instructions for using the TOXTRAP tube.

MALFUNCTIONS AND DISPLAYED ERROR MESSAGES

"NOT READY" And The Diagnostic Checks

Initial status and diagnostic checks.

Displayed Error Messages

Lists error messages and corrective actions.

PREVENTATIVE MAINTENANCE AND SERVICE

Ventilation and Placement

Locating instrument for clearance and ventilation.

User-Serviceable Parts

Fuse and power cord are user-serviceable.

Test Data Entry Sequence For Florida (HRS Implied Consent)

S10 Set time

Setting the instrument's time.

S11 Set date

Setting the instrument's date.

Test Data Entry Sequence

1. Switch Priorities

Explains switch priority logic.

Obtaining A Printout

Diagnostic Check And Printout

Steps to get a printout of diagnostic checks.

Passed Diagnostic Checks

Evidence Card Format

Example of evidence card for passed checks.

Failed Diagnostic Check

Evidence Card Format

Example of evidence card for failed checks.

THE CUSTOM BREATH TEST MODE SEQUENCE WITH SAMPLE CAPTURE

Sample Capture Option Activated

Operations for custom sequence with sample capture.

THE CONTROL BREATH TEST MODE SEQUENCE

Sample Capture Not Activated

Operations for control sequence without sample capture.

12. "CONTROL TEST .###"

Analyzes alcohol vapor from simulator.