EasyManua.ls Logo

CMT DAF-001 User Manual

Default Icon
2 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
1. BUTTONS AND LCD DISPLAY
2. MEASURING IN ABSOLUTE (ABS) MODE
3. USING A HIGH QUALITY LEVEL VIAL
4. ANALOGUE QUADRANT FOR MOVING BLADE
5. LOCKING YOUR DIGITAL ANGLE FINDER FOR MEASURING
ON
OFF
HOLD
ZERO
ABS
A. ABS mode.
B. Press longer than eight seconds to turn your device off;
short press to turn LCD off.
C. Records the last measured value.
D. Switch between absolute and relative measuring mode
by short pressing the button.
E. High resolution: 0.05°
F. Analogue quadrant showing.
Under ABS mode,
press ZERO/ABS
for five seconds
to set the moving
blade to zero.
Place the moving blade in the same
position of the fixing blade.
Standard level surface.
Make different measuring by locking at four different locking holes.
Notice: measuring range can reach 360° after screwing off the locking knob.
Measuring range: -45° ~180° Measuring range: 0° ~225°
Measuring range: -180° ~45° Measuring range: -225° ~0°
Plumb surface
for measuring.
(1) Device automatically
resets to the original zero
position after shutting off.
(2) Device even makes
upright measurements.
Under ABS mode
- Position in the quadrant: 45°.
- Display range of quadrant is 360°.
-45°
45°
-0.05°
45.05°
0.05°
90°
DIGITAL
ANGLE
FINDER
DAF-001
DIGITAL
ANGLE
FINDER
www.cmtorangetools.com
Clean digital angle finder with mild
liquid soap and a damp cloth.
Never dip into water.
Don’t mark bar with any electric
engraver or scratch it.
DAF-001
1. Metal moving blade
on the front.
2. Aluminium fixing blade.
3. LCD display.
4. Locking knob.
Four holes for locking when measuring
specific angles. Measuring range can reach 360°
after screwing off the locking knob.
Lock the moving blade
at any angle, make precise
drawings and cut directly.
Holes for locking.
Analogue quadrant
showing.
PowerHigh Resolution
3V CR2032
lithiun battery
B C D
03.55.0135 VERS-2022-06
Imported by
WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov
21
PAP
BATTERY
INCLUDED
(CR2032-3V)
INSTRUCTION
EN ES FR IT DE PL RU
Question and Answer IconNeed help?

Do you have a question about the CMT DAF-001 and is the answer not in the manual?

CMT DAF-001 Specifications

General IconGeneral
BrandCMT
ModelDAF-001
CategoryCamera Accessories
LanguageEnglish

Summary

Digital Angle Finder Buttons and Display

Button Functions and Modes

Details functions of ABS, HOLD, ZERO/ABS, and ON/OFF buttons for measurement modes.

Display Features and Resolution

Highlights high resolution (0.05°) and the analogue quadrant display.

Absolute Mode Measurement

Zeroing and Operation in ABS Mode

Instructions for setting the moving blade to zero and device behavior in ABS mode.

Level Vial Usage

Analogue Quadrant and Locking Mechanism

Quadrant Display and Range

Describes the analogue quadrant's angle display range and specific position indicators.

Locking Blade for Precision

Explains using locking holes for stable measurements and precise drawing/cutting.

Digital Angle Finder Locking Options

Safety and Maintenance Notice