Users/Installers must wear protective clothing when handling materials like firebricks, fire cement, adhesives, insulation, and kerosene oil.
The Severn Stove is designed for space heating only, with its burning rate controlled by manual levers.
Chimney height must be at least 5.5m, and the structural flue diameter not less than 200mm.
Check existing chimneys for air leakage or porosity and ensure they are rectified before installation.
Use acid-resistant liners (min 200mm diameter) and consult Building Inspector for chimney repairs.
Recommended internal face is refractory lined, complying with BS 4543, with a minimum diameter of 175mm.
Terminate chimneys above roof level per Building Regulations to avoid downdraught issues.
Rectangular recess required: 975mm wide, 350mm deep, and 1320mm height for top flue outlet.
Provide a 100cm² air vent to outside air and avoid extractor fans in the same room.
Ensure flue pipe extends 150mm into brickwork, avoid horizontal runs, and seal all joints airtight.
Extended lengths of horizontal pipework must be avoided and shall not exceed 150mm.
Open firedoors, ignite fuel with air slides open, and check for seal soundness and flue function.
Contractor must demonstrate operation, riddling, throat plate lowering, and flue cleaning to the user.
The stove uses eight grate bars of one type and seven of another, fitting into specific positions.
150mm diameter black painted C.I. flue pipes and replacement parts are available through local stockists.