EasyManua.ls Logo

Cobra microTALK FRS 110 - microTALK Specifications

Cobra microTALK FRS 110
14 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
C.TRANSMITTER
UNIT NOMINAL
1. EFFECTIVE RADIATED POWER mW 500
2. CARRIER FREQ.STABILITY H z 200
3. MODULATION LIMITING KHz 2.5
4. CARRIER ATTACK TIME mS 30
5. AUDIO FREQUENCY RESPONSE
@ 300 HZ dB -10
@ 2500 HZ dB 4
6. AUDIO DISTORTION % 3
7. HUM NOISE dB 38
8. TRANSIENT FREQ.BEHAVIOR
a) TX ON mS 30
b) TX OFF mS 5
D.POWER SUPPLY
1. BATTERY LIFE (1:1:18 RATIO) HR 24
2. BATTERY V 4.2 - 6.0
Specifications
17
Specifications
16
I.GENERAL SPECIFICATIONS
A. FREQUENCIES
CHANNEL ASSIGNMENT
CH 1: 462.5625MHz CH 8: 467.5625MHz
CH2: 462.5875MHz CH 9: 467.5875MHz
CH 3: 462.6125MHz CH 10: 467.6125MHz
CH 4: 462.6375MHz CH 11: 467.6375MHz
CH 5: 462.6625MHz CH 12: 467.6625MHz
CH 6: 462.6875MHz CH 13: 467.6875MHz
CH 7: 462.7125MHz CH 14: 467.7125MHz
B.RECEIVER
UNIT NOMINAL
1. SENSITIVITY
FOR 12 DB SINAD dBm -119
FOR CALL SIG.DETECTION dB m -121
2. MAX. AUDIO OUTPUT @10% THD mW 150
3. MAX.S/N RATIO @ 1mV RF INPUT dB 45
4. SQUELCH
a) SENSITIVITY dB m -121
b) ATTACK TIME mS 120
c) CLOSING TIME mS 200
5. AUDIO FREQUENCY RESP.
@ 300 HZ dB -15
@ 2500 HZ dB -10
6. SIGNAL DISPLACEMENT BW +/-KHZ 5
7. ADJACENT CH.REJECTION dB 60
8. INTERMODULATION REJECTION dB 65
9. SPURIOUS RESPONSE REJECTION dB 65

Related product manuals