EasyManuals Logo

Cobra mini User Manual

Cobra mini
Go to English
104 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #19 background imageLoading...
Page #19 background image
19
EN
Overview of the cobra
®
systems
APPLICATION AREA INSTALLATION HEIGHT NOTE
cobra 2t
Dynamic breakage cabling up
to branch base diameter of 40
cm (16 in.).
Load/support cabling up to
30 cm (12 in.) branch base
diameter.
Installation position as dynam-
ic breakage cabling at 2/3 the
height of the part of the tree to
be supported.
When used as load/support
cabling, the cable should
be installed as vertically as
possible.
According to ZTV Baumpflege
(the German tree care stand-
ard), cobra 2t is a tree cabling
system with a minimum tensile
strength of 2 tonnes (20 kN).
cobra 4t
Dynamic breakage cabling up
to branch base diameter of 40
to 60 cm (16 to 24 in.).
Static breakage cabling and
load/support cabling up to
branch base diameter of 40
cm (16 in.).
Installation position as dynam-
ic breakage cabling at 2/3 the
height of the part of the tree to
be supported.
When used as load/support
cabling, the cable should
be installed as vertically as
possible.
According to ZTV Baumpflege,
cobra 4t is a tree cabling
system with a minimum tensile
strength of 4 tonnes (40 kN).
cobra 8t
Dynamic breakage cabling up
to branch base diameter of 60
to 80 cm (24 to 32 in.).
Static breakage cabling and
load/support cabling up to
branch base diameter of 40
to 60 cm (16 to 24 in.). Double
installation for branch base
diameter of 60 to 80 cm (24
to 32 in.).
Installation position as dynam-
ic breakage cabling at 2/3 the
height of the part of the tree to
be supported.
When used as load/support
cabling, the cable should
be installed as vertically as
possible.
According to ZTV Baumpflege,
cobra 8t is a tree cabling
system with a minimum tensile
strength of 8 tonnes (80 kN).
minicobra
Securing plants, fruit growing,
crown correction
Installation position for crown
correction as required
cobra
ultrastatic
Static breakage cabling and
load/support cabling up to
branch base diameter of 40
cm (16 in.).
Installation position at 2/3 the
length of the part of the tree to
be supported. When installed
at two levels, static cabling is
fitted at 1/4 the length of the
part of the tree to be braced.
When used as load/support
cabling, the cable should
be installed as vertically as
possible.
According to ZTV Baumpflege,
cobra ultrastatic is a tree
cabling system with a minimum
tensile strength of 4 tonnes
(40 kN).

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Cobra mini and is the answer not in the manual?

Cobra mini Specifications

General IconGeneral
BrandCobra
Modelmini
CategoryCables and connectors
LanguageEnglish