35
1 Stop blasting and push the safety switch back. (This activates the
safety).
2 For the AeRO 75 slide open the hopper
access door and scoop out the remaining
dry ice from the hopper. For the AeRO 75-
DX, just slide the hopper out to empty any
remaining ice.
3 Turn OFF the compressed air supply.
4 Turn the power switch OFF (O) to shut off the power.
5 Turn the Bleed Valve ON (I) to evacuate all remaining
pressure.
6 If open, close the Fill Lid.
7 When the air hose is fully depressurized, disconnect all electric cables,
then the hoses, and wrap them around the hose hangers.
Operation
Shutting Down