INSTALLATION INSTRUCTIONS FOR
MODEL 7330D3351 & 7330D3361 WALL THERMOSTAT
APPLICATION
These thermostats are designed to operate all R.V. Products
ceiling assemblies, which control the air conditioner 115
VAC circuits through 12 VDC relays.
Wiring is required between the thermostat and the ceiling
assembly. The thermostat wiring is field installed and must
be considered before wall paneling and ceiling panels are in
place. Wall thermostat controlled air conditioners are
normally OEM (Original Equipment Manufacturer) installed.
Wall thermostat controlled air conditioners may be installed
for aftermarket applications, with additional considerations
given to the thermostat wire routing.
The 7330D3351 thermostat may also operate any RV furnace
12 VDC control circuit not exceeding one amp. All
thermostats are equipped with a replaceable 2 amp fuse
located on the back of the thermostat body.
INSTALLATION INSTRUCTIONS
BE SURE ALL ELECTRICAL POWER HAS BEEN
DISCONNECTED FROM THE AIR CONDITIONER,
THE CEILING ASSEMBLY AND THE POWER
SUPPLY.
These instructions are provided for the proper mounting of
the thermostat itself. An Operation Chart and Terminal
Cross Reference Chart are provided to show thermostat
capabilities.
Wiring procedure is dependent upon the ceiling assembly to
be matched with this component, and is provided in the
ceiling assembly installation instructions.
Recreation Vehicle Products suggests the thermostat wiring
be minimum 18 gauge.
A. THERMOSTAT LOCATION
This thermostat is a sensitive instrument. For accurate
temperature control and comfort, the following considerations
should be taken into account:
1. Locate the thermostat on an inside wall about five
feet above the floor. Pick a dry area where air
circulation is good. The thermostat should be
mounted within a reasonable distance from the
appliance the thermostat will control. This will
assure a more accurate temperature relationship
between the thermostat and the appliance the
thermostat will control.
2. Do not install the thermostat where there are unusual
heating conditions; such as direct sunlight, heat
producing appliances (television, radio, wall lamp,
etc.) or a furnace or air conditioner supply register.
B. ROUTING THE THERMOSTAT
WIRE BUNDLE
A separate wire bundle to power the 12 VDC thermostat will
need to be routed between the thermostat and the power
supply. Both positive and negative must be brought up to the
thermostat.
If a 12 VDC furnace is also to be operated, additional wiring
will need to be routed and a definite furnace location defined.
See Figure 1.
1. Route the wire bundle between the thermostat and
the ceiling assembly. Allow an additional 6 inches
of length at both the thermostat and the ceiling
assembly. This will give the installer the required
slack necessary for wiring. See Figure 1.
2. Route the separate 2 wire thermostat bundle between
the thermostat and the power supply. Allow 6
inches of additional wiring on both ends. See
Figure 1.
3. If a 12 VDC furnace is to be operated, route a wire
bundle between the thermostat and the furnace.
Allow an additional 6 inches at both ends. See
Figure 1.
4. If stapling the wire bundle during the routing
process, be careful not to pierce the thermostat
wiring insulation.
C. ATTACHING THE WALL THERMOSTAT
1. Separate the thermostat body from the sub-base by
gently pulling at the top and bottom. See Figure 2.
2. If this thermostat is a replacement thermostat for one
which has failed or no longer meets the needs of the
system: note the thermostat wiring on the back of the
old thermostat sub-base, and the system function
each wire was operating. This will save time and
trouble when rewiring the new thermostat. Before
removing the thermostat wiring from the old
thermostat, make sure the power supply to the
thermostat is disconnected.
Question and Answer IconNeed help?

Do you have a question about the Coleman 7330D3351 and is the answer not in the manual?

Summary

Thermostat Application and Location

Application Overview

Thermostats control RV air conditioners via 12 VDC relays and can also operate RV furnaces.

Thermostat Location Considerations

Locate thermostat on an inside wall, about five feet above the floor, in a dry area with good air circulation.

Unsuitable Installation Locations

Do not install where there are unusual heating conditions like direct sunlight or heat-producing appliances.

Thermostat Wire Routing

Routing Thermostat Wire Bundle

Route a separate 12 VDC wire bundle between the thermostat and the power supply, allowing extra slack.

Routing Furnace Wire Bundle

If operating a 12 VDC furnace, route an additional wire bundle between the thermostat and the furnace.

Wire Stapling Caution

When routing wires, be careful not to pierce the thermostat wiring insulation if using staples.

Wall Thermostat Installation

Attaching the Sub-base

Separate the thermostat body from the sub-base by gently pulling, then attach the sub-base to the wall.

Wiring Procedure

Strip wire ends, use the Wire Cross Reference Chart, and connect wires to the thermostat terminals.

Power Supply Connection

Attach the 12 volt power supply wires to the appropriate terminals, ensuring correct polarity.

Securing the Thermostat Body

Gently push excess wiring back into the wall, fill the opening with insulation, and snap the body onto the base.

Thermostat Operation

System Function Chart

Chart details system functions based on switch positions for the 7330D3351 and 7330D3361 models.

Cooling Function Delay

All cooling functions have a short cycle protection time delay of 3 minutes.

Summary

Thermostat Application and Location

Application Overview

Thermostats control RV air conditioners via 12 VDC relays and can also operate RV furnaces.

Thermostat Location Considerations

Locate thermostat on an inside wall, about five feet above the floor, in a dry area with good air circulation.

Unsuitable Installation Locations

Do not install where there are unusual heating conditions like direct sunlight or heat-producing appliances.

Thermostat Wire Routing

Routing Thermostat Wire Bundle

Route a separate 12 VDC wire bundle between the thermostat and the power supply, allowing extra slack.

Routing Furnace Wire Bundle

If operating a 12 VDC furnace, route an additional wire bundle between the thermostat and the furnace.

Wire Stapling Caution

When routing wires, be careful not to pierce the thermostat wiring insulation if using staples.

Wall Thermostat Installation

Attaching the Sub-base

Separate the thermostat body from the sub-base by gently pulling, then attach the sub-base to the wall.

Wiring Procedure

Strip wire ends, use the Wire Cross Reference Chart, and connect wires to the thermostat terminals.

Power Supply Connection

Attach the 12 volt power supply wires to the appropriate terminals, ensuring correct polarity.

Securing the Thermostat Body

Gently push excess wiring back into the wall, fill the opening with insulation, and snap the body onto the base.

Thermostat Operation

System Function Chart

Chart details system functions based on switch positions for the 7330D3351 and 7330D3361 models.

Cooling Function Delay

All cooling functions have a short cycle protection time delay of 3 minutes.

Coleman 7330D3351 Specifications

General IconGeneral
BrandColeman
Model7330D3351
CategoryThermostat
LanguageEnglish