RI820251 - 04/18 - ind. A
3 9
.Pressure lost or iron in
conditioned water.
A. ron in the water supply pipe.
B. ron mass in the softener.
C. Fouled resin bed.
D. Too much iron in the raw
water.
A. Clean the water supply pipe.
B. Clean valve and add resin cleaning chemical
increase freuency of regeneration.
C. Check backwash brine draw and brine tank refill.
ncrease freuency of regeneration and backwash
time.
D. ron removal euipment is reuired to install
before softening.
drain line.
B. Bottom strainer broken.
C. mproperly sied drain line
control.
A. Assure that well system has proper air eliminator
control.
B. Replace the bottom strainer.
C. Check for proper drain rate.
continuously.
B. Time of regeneration steps
were set to ero
C. Locating signal wiring break
down
D. Foreign material stuck the
driving gear.
A. Replace the controller.
B. Check program setting and reset.
C. Check and connect locating signal wiring.
D. Take out foreign material.
continuously.
B. When electricity fails to
supply valve stops backwash or
fast rinse position.
C. Control valve is in Backwash
status.
A. Check and repair valve body or replace it.
B. Adjust valve to service position or turn off bypass
valve and restart when electricity supply.
water.
A. Foreign material in injector or
injector fails to work.
B. Brine valve cannot be shutoff.
C. Time of rapid rinse too short.
A. Clean and repair injector.
B. Repair brine valve and clean it.
C. Etend rapid rinse time.
irregular brine.
A. Water pressure too low or not
stable.
B. njector is plugged or faulty.
C. Air in resin tank.
D. Floccules in resin tank during
backwash.
A. ncrease water pressure.
B. Clean or replace injector.
C. Check and find the reason.
D. Clean the floccules in resin tank.