13.Water flow out from
drain or brine pipe after
regeneration.
A. Foreign material in valve
which makes valve cant be
closed completely.
B. Hard water mied in
valve body.
C. Water pressure is too high
which result in valve doesnt get
the right position.
A. Clean foreign material in valve body.
B. Change valve core or sealing ring.
C. Reduce water pressure or use
pressure release function.
14.Cycle water treat
capacity decreases.
A. nit fails to regenerate or
regenerate not properly.
B. Fouled resin bed.
C. alt setting not proper.
D. oftener setting not proper.
E. Raw water uality
deterioration.
F. Turbine of flow meter is stuck.
A. Regenerate according to the correct operation
reuirement.
B. ncrease backwash flow rate and time clean or
change resin.
C. Readjust brine drawing time.
D. According to the test of outlet water recount and
reset.
E. Regenerate unit by manual temporary then reset
regeneration cycle.
F. Disassemble flow meter and clean it or replace it
with a new turbine.
15. Leak By Pass
A. ring of the piston defective
B. Network overpressure
A. Replace By Pass
Check the pressure reducer upstream of the device
1. Black screen
A. No power supply
B. Power transformer defective
water softener
C. Defective Motherboard
A. Control the socket
B. Replace the transformer
C. Replace the Motherboard
1. Air in the pipes A. Air intake during regeneration
A. Check the white pipe between the valve and the
float connection tightening
Pass the float to the water
Change the float
B. Controller Fault