CSB200 Class B AIS
R4.0 16
SERIAL DATA INTERFACE
Data Connection
If an external display unit is to be used to show other AIS units within
range (such as a chart plotter, PC serial terminal or other display device)
connect the user end of the data interface cable to the display device.
Note that the software in the display device must be configured for AIS
operation.
There is a 9-way D-type female connector mounted at the rear of the
CSB200. The standard wire ended data cable assembly provided mates
with this connector.
9 Pin D
Cable Colour
Signal Name
1
BROWN
-NMEA Output (RS422)
2
RED
+RS232 Output
3
ORANGE
+RS232 Input
4
YELLOW
+NMEA Output (RS422)
5
GREEN
Ground
6
BLUE
TX Off Switch +
7
VIOLET
Not Used
8
GREY
+NMEA Input (RS422)
9
BLACK
-NMEA Input (RS422)