instruction for the service people
27
PROBLEMS TROUBLE SHOOTING
Machine with steam heating
make sure that the steam valve is open and
that there is steam at a pressure not less 0,5
bar (50 kPa)
make sure that the filter of the condense trap
is not blocked
make sure that the steam solenoid valve
"YV10" is working.
make sure that the filter of the steam strainer
is not blocked, thus restricting the normal
flow of steam.
make sure that the steam condensate is being
discharged freely.
make sure that the steam heating coil is not
encrusted, thus limiting heat exchange.