26
MOTOR PUMP IDENTIFICATION PLATE
WARNING
•Shouldtheidenticationplatedeteriorateduringuse,contacttheManufacturerora
Skilled Technician
to
haveitrestored.
eidenticationplate(12)showsthemotorpumpmodel,theserialnumber,theyearofmanufactureandthe
mainelectricalandmechanicalspecications(maxrotationspeed,maxpressure,weight,powersupplyvoltage,
input,etc.).Itislocatedonthebaseofthemotorpump(allversionswithcombustionengine,MTPMC20/20
andMTPMC25withelectricmotor),oronthepowerbox(remainingmotorpumpswithelectricmotor).
SAFETY DEVICES
WARNING
•emachineinwhichthemotorpumpisintegratedmustalwaysfeatureasafetyvalve,i.e.,amaxpressure
valve,suitablycalibrated,whichdischargesexcesspressureincaseofafaultinthehigh-pressurecircuit:inthe
eventofthesafetyvalvetrippingfrequently,immediatelystopusingthemachineinwhichthemotorpumpis
integratedandhaveitcheckedbya
Skilled Technician
.
a) Pressure unloader/regulation valve.
isvalveissuitablysetbytheManufacturerandallowsregulatingtheoperatingpressureandpermitsthe
pumpeduidtoowbacktowardsthebypassduct,thuspreventingtheaccumulationofdangerouspressures
whenthedeliverylineisclosedorwhenattemptsaremadetosetpressurevaluesabovethemaximumones
allowed.Apressureunloader/regulationvalvefeaturingpumpedliquidon/odevices(suchastaps)isusually
called
control unit
.
WARNING
•epressureunloader/regulationvalveisseteitherbythemotorpumpManufacturerorbythatofthemachine
inwhichthemotorpumpisintegrated.
Never try and adjust the pressure unloader/regulation valve to
alter the setting: only operate on this by means of the knob(3).
b)
ermal or ampere cut-out protection device.
isdevicestopsmotorpumpoperationintheeventofoverheatingoftheelectricmotororexcessivepower
absorption respectively.
Ifoneofthesetrips,proceedasfollows,
keeping to the indications shown in the manual of the machine in
which the motor pump is integrated:
• stopthemachineandremovetheplugfromthepowersocket;
• releaseanyresidualpressureinthehigh-pressurecircuit;
• wait10÷15minutesforthemotorpumptocooldown;
• makesuretheinstructionshavebeenfollowedintheparagraph
“checkIng and connectIng up to the power
supply
,withspecialreferencetoanyextensionused;
• ttheplugbackinthesocketandrepeatthestartprocedure.
WARNING
•Incasethesesafetydevicestripfrequently,donotusethemotorpump(andthereforethemachineinwhichit
isintegrated)withoutrsthavingitcheckedbya
Skilled Technician
.