SPLIT-TYPE ROOM AIR CONDITIONER
Owner’s Manual &
Installation Manual
IMPORTANT NOTE:
Please check the applicable models, technical
data, F-GAS(if any) and manufacturer information
from the “Owner's Manual - Product Fiche ”
in the packaging of the outdoor unit.
(European Union products only)
Read this manual and SAFETY MANUAL(if any)
carefully before installing or operating your new
air conditioning unit. Make sure to save this
manual for future reference.
AF-09HRFN8-I V1
AF-12HRFN8-I V1
AF-18HRFN8X IN 2021
AF-24HRFN8X IN 2021
AF-09HFN8-O V1
AF-12HFN8-O V1
AF-18HRFN8X OU 2021
AF-24HRFN8X OU 2021

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Comfee AF-09HRFN8-I V1 and is the answer not in the manual?

Overview

This document is an Owner's Manual and Installation Manual for a Split-Type Room Air Conditioner manufactured by Comfee. It covers various models including AF-09HRFN8-I V1, AF-12HRFN8-I V1, AF-18HRFN8X IN 2021, AF-24HRFN8X IN 2021 for indoor units, and AF-09HFN8-O V1, AF-12HFN8-O V1, AF-18HRFN8X OU 2021, AF-24HRFN8X OU 2021 for outdoor units. The manual emphasizes reading safety precautions before operation and installation and saving it for future reference. For European Union products, it directs users to check the "Owner's Manual - Product Fiche" in the outdoor unit packaging for applicable models, technical data, F-GAS, and manufacturer information.

Function Description

The Comfee Split-Type Room Air Conditioner is designed to provide cooling, heating, and dehumidification for indoor spaces. It consists of an indoor unit and an outdoor unit connected by refrigerant piping and electrical cables. The unit can be controlled via a remote control (some units include a remote control holder) and, for some models, wirelessly via a mobile phone.

Operating Modes: The air conditioner supports COOL, HEAT, and DRY modes.

  • COOL mode: Operates within a room temperature range of 17°C - 32°C (62°F - 90°F). Outdoor temperature ranges vary by model type:
    • Inverter Split Type: 0°C - 50°C (32°F - 122°F); -15°C - 50°C (5°F - 122°F) for low temp. cooling systems; 0°C - 52°C (32°F - 126°F) for special tropical models.
    • Fixed-speed Type: 18°C - 43°C (64°F - 109°F); -7°C - 43°C (19°F - 109°F) for low-temp cooling systems; 18°C - 52°C (64°F - 126°F) for special tropical models.
  • HEAT mode: Operates within a room temperature range of 0°C - 30°C (32°F - 86°F). Outdoor temperature ranges vary by model type:
    • Inverter Split Type: -15°C - 30°C (5°F - 86°F).
    • Fixed-speed Type: 0°C - 30°C (32°F - 86°F); -7°C - 24°C (19°F - 75°F) for low-temp cooling systems; 18°C - 52°C (64°F - 126°F) for special tropical models.
  • DRY mode: Operates within a room temperature range of 10°C - 32°C (50°F - 90°F). Outdoor temperature ranges vary by model type:
    • Inverter Split Type: 0°C - 50°C (32°F - 122°F); 0°C - 52°C (32°F - 126°F) for special tropical models.
    • Fixed-speed Type: 10°C - 32°C (50°F - 90°F); 11°C - 43°C (52°F - 109°F); 18°C - 43°C (64°F - 109°F); 18°C - 52°C (64°F - 126°F) for special tropical models.

Special Features (some units):

  • Auto-Restart: Automatically restarts with prior settings after a power loss.
  • Anti-mildew: Dries condensed water at very low power after turning off from COOL, AUTO (COOL), or DRY modes to prevent mildew growth.
  • Wireless Control: Allows control via a mobile phone and wireless connection. USB device access, replacement, and maintenance require professional staff.
  • Louver Angle Memory: Louver automatically resumes its former angle upon unit startup.
  • Refrigerant Leakage Detection: Indoor unit displays "EC" or "ELOC" or flashes LEDs when leakage is detected.
  • Sleep Operation: Decreases energy use during sleep by gradually adjusting temperature. Not available in FAN or DRY mode. Stops after 8 hours.
  • 8°C Heating Feature: Indicated by "FP" on the display (some units).
  • Fresh and UV-C lamp: Indicated by "fresh" on the display (some units).
  • Self-cleaning: Indicated by "SC" on the display (some units).
  • Anti-cold air: Indicated by "CF" on the display (some units).

Important Technical Specifications

Refrigerant Types: The units may use R32 or R290 refrigerants. For R32 and R290 models, only blast-proof ceramic fuses can be used.

  • R32 refrigerant models: Appliance must be installed, operated, and stored in a room with a floor area larger than 4m².
  • R290 refrigerant models: Appliance must be installed, operated, and stored in a room with a floor area larger than:
    • <=9000Btu/h units: 13m²
    • 9000Btu/h and <=12000Btu/h units: 17m²

    • 12000Btu/h and <=18000Btu/h units: 26m²

    • 18000Btu/h and <=24000Btu/h units: 35m²

    • Reusable mechanical connectors and flared joints are not allowed indoors (EN Standard Requirements).
    • Mechanical connectors used indoors shall have a rate of not more than 3g/year at 25% of the maximum allowable pressure. Sealing parts must be renewed if connectors are reused. Flare parts must be re-fabricated if flared joints are reused (UL Standard Requirements).
    • Mechanical connectors used indoors must comply with ISO 14903.
    • Total amount of R290 refrigerant to be charged is limited: 387g (<=9000Btu/h), 447g (>9000Btu/h and <=12000Btu/h), 547g (>12000Btu/h and <=18000Btu/h), 632g (>18000Btu/h and <=24000Btu/h).
    • Mixing refrigerant types is prohibited.

Fuse Specifications: The air conditioner's circuit board (PCB) includes a fuse for overcurrent protection. Fuse specifications are printed on the PCB (e.g., T3.15AL/250VAC, T5AL/250VAC, T3.15A/250VAC, T5A/250VAC, T20A/250VAC, T30A/250VAC).

Electrical Connections:

  • All wiring must comply with local and national electrical codes and regulations.
  • Power voltage should be within 90-110% of rated voltage.
  • If connecting to fixed wiring, a surge protector and main power switch are required. An all-pole disconnection device with at least 3mm clearances in all poles and a residual current device (RCD) with a rated residual operating current not exceeding 30mA must be incorporated.
  • Minimum cross-sectional area of power and signal cables (for reference, not applicable for North America) is provided based on rated current (e.g., >3 and ≤6A requires 0.75mm², >32 and ≤40A requires 6mm²).
  • For North America, cable type and size should follow local electrical codes and Minimum Circuit Ampacity on the nameplate.

Refrigerant Piping:

  • Minimum pipe run of 3 meters is required to minimize vibration and excessive noise.
  • Maximum length and drop height of refrigerant piping vary by model capacity:
    • <15,000 BTU/h: Max. Length 25m (82ft), Max. Drop Height 10m (33ft).
    • ≥15,000 and <24,000 BTU/h: Max. Length 30m (98.5ft), Max. Drop Height 20m (66ft).
    • ≥24,000 and <36,000 BTU/h: Max. Length 50m (164ft), Max. Drop Height 25m (82ft).
  • For R290 refrigerant models, the maximum length of refrigerant pipe should not exceed 10 meters (32.8ft).
  • Additional refrigerant charging is calculated based on pipe length and refrigerant type (R32, R290, R410A, R22).
  • Minimum bend radius for connective refrigerant piping is 10cm.

Impedance Information (for specific models):

  • MSAFB-12HRN1-QC6: Connects to a supply with system impedance no more than 0.373Ω.
  • MSAFD-17HRN1-QC5: Connects to a supply with system impedance no more than 0.210Ω.
  • MSAFD-22HRN1-QC6: Connects to a supply with system impedance no more than 0.129Ω.

Usage Features

Indoor Unit Display: The indoor unit display shows various indicators depending on the model:

  • "fresh": Fresh and UV-C lamp feature activated.
  • "defrost": Defrost feature activated.
  • "run": Unit is on.
  • "timer": Timer is set.
  • "ח": Wireless Control feature activated.
  • "88": Displays temperature, operation feature, and error codes.
    • When ECO function is activated, '88' illuminates gradually.
    • "07" for 3 seconds: TIMER ON is set, or FRESH, UV-C lamp, SWING, TURBO, or SILENCE feature is turned on.
    • "OF" for 3 seconds: TIMER OFF is set, or FRESH, UV-C lamp, SWING, TURBO, or SILENCE feature is turned off.
    • "CF": Anti-cold air feature turned on.
    • "AF": Defrosting (cooling & heating units).
    • "SC": Unit is self-cleaning.
    • "FP": 8°C heating feature turned on.

Air Flow Control:

  • Vertical Angle: Set using the SWING/DIRECT button on the remote control. Avoid setting too vertical an angle in COOL or DRY mode to prevent condensation. In COOL or HEAT mode, avoid too small an angle to prevent restricted airflow.
  • Horizontal Angle: Manually adjusted by gripping the deflector rod. Some units allow remote control adjustment.

Manual Operation (without Remote): For testing or emergency use when the remote is lost:

  1. Open the front panel of the indoor unit.
  2. Locate the MANUAL CONTROL button.
  3. Press once for FORCED AUTO mode.
  4. Press again for FORCED COOLING mode.
  5. Press a third time to turn the unit off.
  6. Close the front panel.

Maintenance Features

Cleaning Your Indoor Unit:

  • Turn off and disconnect power before cleaning.
  • Use a soft, dry cloth; for dirty units, a cloth soaked in warm water.
  • Do not use chemicals, chemically treated cloths, benzene, paint thinner, polishing powder, or solvents.
  • Do not use water hotter than 40°C (104°F) on the front panel.

Cleaning Your Air Filter: Clean the air filter every two weeks to maintain cooling efficiency and health.

  1. Lift the front panel.
  2. Press the tab to loosen the buckle, lift, and pull the filter out.
  3. If present, unclip the small air freshening filter from the larger filter and clean with a handheld vacuum.
  4. Clean the large air filter with warm, soapy water and a mild detergent.
  5. Rinse with fresh water, shake off excess, and dry in a cool, dry place away from direct sunlight.
  6. Re-clip the air freshening filter and slide the filter back into the unit.
  7. Close the front panel.
  • Caution: Do not touch the air freshening (Plasma) filter for at least 10 minutes after turning off the unit.

Air Filter Reminders (Optional):

  • Cleaning Reminder: "CL" flashes after 240 hours of use. Reset by pressing the LED button on the remote 4 times or MANUAL CONTROL button 3 times.
  • Replacement Reminder: "nF" flashes after 2,880 hours of use. Reset by pressing the LED button on the remote 4 times or MANUAL CONTROL button 3 times.

Maintenance - Long Periods of Non-Use:

  • Clean all filters.
  • Turn on FAN function until the unit dries out completely.
  • Turn off the unit and disconnect power.
  • Remove batteries from the remote control.

Maintenance - Pre-Season Inspection:

  • Check for damaged wires.
  • Clean all filters.
  • Check for leaks.
  • Replace batteries.
  • Ensure air inlets and outlets are not blocked.

UV-C Lamp (Applicable to units containing a UV-C lamp only):

  • Do not operate UV-C lamps outside the appliance.
  • Do not operate obviously damaged appliances.
  • Unintended use or damage to housing may result in dangerous UV-C radiation, which can harm eyes and skin.
  • Disconnect power before opening doors and access panels bearing the ULTRAVIOLET RADIATION hazard symbol for user maintenance.
  • The UV-C lamp cannot be cleaned, repaired, or replaced by the user.
  • UV-C BARRIERS bearing the ULTRAVIOLET RADIATION hazard symbol should not be removed.
  • Warning: Do not stare at the light source.

General Safety and Installation Precautions:

  • Installation must be performed by an authorized dealer or specialist according to instructions and national wiring regulations.
  • Only use included accessories and parts.
  • Install the unit in a firm location that supports its weight.
  • Install drainage piping correctly to prevent water damage.
  • Do not install units with auxiliary electric heaters within 1 meter (3 feet) of combustible materials.
  • Do not install in locations exposed to combustible gas leaks.
  • Do not turn on power until all work is completed.
  • Consult service technicians for relocation.
  • Turn off and unplug the unit during storms or if not used for a long time.
  • Ensure water condensation drains unhindered.
  • Do not operate with wet hands.
  • Do not climb onto or place objects on the outdoor unit.
  • Avoid prolonged operation with open doors/windows or high humidity.
  • Ensure proper ventilation if used with burners to avoid oxygen deficiency.
  • For kitchens, server rooms, etc., specially designed AC units are recommended.

European Disposal Guidelines:

  • Waste electrical and electronic equipment should not be mixed with general household waste.
  • Dispose of at designated municipal electronic waste collection facilities.
  • Retailers will take back old appliances when a new one is purchased.
  • Manufacturers will take back old appliances free of charge.
  • Appliances can be sold to certified scrap metal dealers.
  • Improper disposal in natural surroundings can endanger health and the environment due to hazardous substances leaking into groundwater and entering the food chain.

Comfee AF-09HRFN8-I V1 Specifications