A.
E. F.D.B. C.
Kit Includes Tools Required
A.
B.
C.
D.
E.
1- 60343 Motor Mount w/ MM5 series module
2- 40002 8/32 X 1/4” Phillips head screws
1- 50030 8’ Lead w/ VD Connector
1- 50944 Molex Pigtail
1- 40144 Dogging Hole Cap
Cordless Drill
Hammer & Pin Punch(recommend)
3/16 & 3/32 drill bit
5/16 Nut driver (recommended)
#2 Phillips head screwdriver
vLP-UL-M KIT
INSERT Instructions
The Command Access VLP-UL-M-KIT is a Field-installable motorized latch-pullback kit for the Von Duprin 99/98 & 35/33 series
devices.
#20453_c
US customer support 1-888-622-2377 | www.commandaccess.com | CA customer support 1-855-823-3002
SPECIFICATIONS:
Input Voltage: 24VDC +/- 10%
Average Latch Retraction Current: 900mA
Average Holding Current: 200mA
Wire Gauge: Minimum 18 gauge
Direct wire run - no relays or access control units in-between power supply & module
Recommended Power Supplies:
All Command Access exit devices & field installable kits have been thoroughly cycle tested with Command Access power supplies at our factory. If you
plan on using a non-Command power supply it must be a filtered & regulated linear power supply.
G.
Fire rated dogging kit
1- 50872- Fire Rated Drilling Template (Old Devices)
1- Replacement Dogging Tail Piece (40006 + 40800 + 50872)
F.
G.

Questions and Answers

  • C
    Caleb WatersAug 4, 2025
    What to do if my Command access Industrial Equipment beeps 4 times?
    • H
      Heather AndersonAug 4, 2025
      If your Command access Industrial Equipment is emitting 4 beeps, it indicates a failed sensor. First, verify that all 3 sensor wires are correctly installed. If the problem continues, replace the sensor. Contact the office for assistance with sensor replacement.
  • A
    Andrew BradleyAug 11, 2025
    Why does my Command access Industrial Equipment beep 5 times?
    • P
      perryjulieAug 11, 2025
      If your Command access Industrial Equipment is emitting 5 beeps, this indicates a retraction or dogging failure. To reset, depress the bar for 5 seconds at any time.
  • J
    John HebertAug 20, 2025
    How to fix 2 beeps on Command access Industrial Equipment?
    • J
      Jessica Miller DVMAug 20, 2025
      If your Command access Industrial Equipment is emitting 2 beeps, it signifies an over voltage condition. Check the voltage and adjust it to 24V.
  • M
    melissajimenezAug 27, 2025
    What to do if my Command access Industrial Equipment beeps 3 times?
    • W
      watkinstimothyAug 27, 2025
      If your Command access Industrial Equipment is emitting 3 beeps, it indicates an under voltage issue. To resolve this, check the voltage and adjust it to 24 V.

Summary

Technical Information and Diagnostics

Setting PTS

Procedure to enter PTS mode, set new position, and confirm adjustment for the device.

Troubleshooting and Diagnostics

Explanation of beep codes for device status, errors, and troubleshooting steps for common issues.

Installation Instructions

Command access VLP-UL-M KIT Specifications