TRANSFORMER INSTALLATION
When mounting the hypersil transformer, place the HF-2500\HF-2500
MAGNUM so the front panel faces your body. Align the transformer so
the Danger High Voltage label reads right. The wire leads coming out
of the transformer should be to the rear and the connector to the right.
place the transformer in the unit aligning the transformer's mounting
holes to the mounting holes on the bottom of the chassis. Place the 1/4
- 20 screws threw the mounting holes and chassis and secure with the
1/4 - 20 nuts and washers. Connect the male-female "mate & lock"
connector. Push hard to insure that the two halves are locked together.
The transformer should now be installed and ready for use.
TUBE INSTALLATION
Carefully remove the 3CPX800A7 tubes from their shipping carton.
This carton was located in the area where the transformer was
installed. Place the tubes in the tube sockets with the proper pin
alignment. If you have maintained the proper pin alignment, the tubes
should go into their sockets easily. If you have to use undue pressure
to insert the tubes, you may have the wrong pin alignment or one of
the pins may be bent. If necessary straighten pins with needle nose
pliers and reinstall. Install the parasitic chokes on the tube caps and
replace the top and bottom covers. When you reinstall the top and
bottom covers it may be necessary to use an awl to align the screws.