DOOR STATION DRC-nUC/RF1
User Manual
Thank you for purchasing COMMAX products.
Please carefully read this User’s Guide (in particular, precautions for safety) before using a product and follow
instructions to use a product exactly.
The company is not responsible for any safety accidents caused by abnormal operation of the product.
Question and Answer IconNeed help?

Do you have a question about the Commax DRC-4UC/RF1 and is the answer not in the manual?

Summary

Overview and Product Information

Product Features and Cautions

Details on product features and essential safety precautions for operation.

Compatibility Notice

Key information regarding Master unit and house unit compatibility.

How to Use the Door Station

RF Card Key Usage and Registration

Button Functions for RF Card Operations

Description of the buttons used for RF card registration and deletion.

Master Card Registration Process

Step-by-step guide for registering master cards for registration and deletion.

Master Card Registration Remarks

Important notes on master card registration, including limitations and data handling.

Door Release Card Management

Door Release Card Registration

Procedure for registering individual or multiple door release cards.

Individual Card Deletion

Steps to remove specific cards from the system's access list.

All Cards Deletion Process

Process for clearing all registered cards from the device memory.

Card Management Remarks

Important information on card capacity, errors, and cancellation procedures.

Wiring Diagrams for Door Stations

DRC-1 UC;RF1 Wiring

Detailed wiring connections for the DRC-1UC/RF1 model.

DRC-2 UC;RF1 Wiring

Detailed wiring connections for the DRC-2UC/RF1 model.

DRC-3 UC;RF1 Wiring

Detailed wiring connections for the DRC-3UC/RF1 model.

Additional Wiring Diagrams

DRC-4 UC;RF1 Wiring

Wiring diagram for the DRC-4UC/RF1 door station.

DRC-5 UC;RF1 Wiring

Wiring diagram for the DRC-5UC/RF1 door station.

DRC-6 UC;RF1 Wiring

Wiring diagram for the DRC-6UC/RF1 door station.

Product Installation Guide

Installation Position Recommendations

Visual guidance on optimal mounting height and angle for the door station.

Component List

Part Identification and Quantities

List of included parts and their respective quantities for each model.

Technical Specifications

General Specifications

Details on model, power, wiring, communication, light, and camera angles.

Dimension Specifications

Physical dimensions for various DRC models and communication distance.

RF-ID Model Specifications

RF-ID Technical Details

Information on frequency, power range, modulation, and operating temperature.

Summary

Overview and Product Information

Product Features and Cautions

Details on product features and essential safety precautions for operation.

Compatibility Notice

Key information regarding Master unit and house unit compatibility.

How to Use the Door Station

RF Card Key Usage and Registration

Button Functions for RF Card Operations

Description of the buttons used for RF card registration and deletion.

Master Card Registration Process

Step-by-step guide for registering master cards for registration and deletion.

Master Card Registration Remarks

Important notes on master card registration, including limitations and data handling.

Door Release Card Management

Door Release Card Registration

Procedure for registering individual or multiple door release cards.

Individual Card Deletion

Steps to remove specific cards from the system's access list.

All Cards Deletion Process

Process for clearing all registered cards from the device memory.

Card Management Remarks

Important information on card capacity, errors, and cancellation procedures.

Wiring Diagrams for Door Stations

DRC-1 UC;RF1 Wiring

Detailed wiring connections for the DRC-1UC/RF1 model.

DRC-2 UC;RF1 Wiring

Detailed wiring connections for the DRC-2UC/RF1 model.

DRC-3 UC;RF1 Wiring

Detailed wiring connections for the DRC-3UC/RF1 model.

Additional Wiring Diagrams

DRC-4 UC;RF1 Wiring

Wiring diagram for the DRC-4UC/RF1 door station.

DRC-5 UC;RF1 Wiring

Wiring diagram for the DRC-5UC/RF1 door station.

DRC-6 UC;RF1 Wiring

Wiring diagram for the DRC-6UC/RF1 door station.

Product Installation Guide

Installation Position Recommendations

Visual guidance on optimal mounting height and angle for the door station.

Component List

Part Identification and Quantities

List of included parts and their respective quantities for each model.

Technical Specifications

General Specifications

Details on model, power, wiring, communication, light, and camera angles.

Dimension Specifications

Physical dimensions for various DRC models and communication distance.

RF-ID Model Specifications

RF-ID Technical Details

Information on frequency, power range, modulation, and operating temperature.

Overview

The COMMAX DRC-nUC/RF1 is a door station designed for smart homes and security systems, offering communication and access control functionalities. It serves as a master unit capable of calling and communicating with multiple house units.

Function Description:

The primary function of the DRC-nUC/RF1 is to facilitate communication between visitors at the door and residents inside the house. When a visitor presses a call button on the door station, it initiates a call to the corresponding household phone or video phone. Residents can then answer the call and engage in two-way communication (duplex hands-free). The device also supports 3-way communication if another user activates their monitor while a conversation is ongoing with the door camera user.

A key feature of this door station is its integrated RF card key reader, which allows for convenient door access. Users can tag a registered RF card key to the designated "CARD" point on the device to open the door. The device includes a lighting sensor and white LED lights to illuminate the name label, ensuring visibility in various lighting conditions.

Important Technical Specifications:

  • Model Name: DRC-nUC/RF1 (where 'n' indicates the number of households that can be called, with 1UC to 6UC variants available).
  • Power Source: DC12V, 1A.
  • Wiring: 4 Wires (Polarity).
  • Communication: Hands-free (Duplex).
  • Min. Lux: 0.1Lux (up to 300mm from the camera).
  • Light: White LED (3pie) 2EA Built-In.
  • Camera Angle: Horizontal: 82°, Vertical: 66.5°.
  • Angle: Up 13°, Down 13°.
  • Camera Module: C-MOS.
  • Temperature: -20°C to +50°C (tested up to -40°C), 95% humidity.
  • Dimensions (W x H x D):
    • DRC-4UC/RF1, 5UC/RF1, 6UC/RF1: 142mm x 315mm x 50mm.
    • DRC-1UC/RF1, 2UC/RF1, 3UC/RF1: 130mm x 250mm x 50mm.
  • RF-ID Model Specifications:
    • Frequency: 13.56MHz.
    • Antenna Power Range: Under 47.5mV/m within a 10-meter radius.
    • Power: DC 5V.
    • Emission Type: A1D.
    • Number of Channel: 1 Channel.
    • Modulation Method: ASK.
    • Communication Method: Simplex Operation Method.
    • Temperature: -20°C to +50°C (tested up to -40°C), 95% humidity.

Usage Features:

  • Multi-Unit Calling: The 'n' in DRC-nUC/RF1 signifies its capability to call up to 'n' number of house units (e.g., 1UC for one unit, 6UC for six units). Users should be careful to press the correct call button to avoid mistakenly calling other households.
  • RF Card Key Access: The device supports door opening via RF card keys. Users can register and delete individual or all RF cards.
  • Master Card Registration/Deletion: A master card is used for both registering and deleting door release cards.
    • Registration: Press button 1, tag the master card, then tag individual door release cards.
    • Deletion: Press button 2, tag the master card, then press button 3 for individual deletion or hold button 3 for 5 seconds for all card deletion.
  • Visual and Auditory Feedback: LED flickers and beep sounds indicate different modes (e.g., slow flicker for registration, fast flicker for deletion).
  • Installation: The device is designed for wall mounting, with recommended installation heights (145cm to 170cm from the ground, with the camera positioned at an angle of 13° upward and 13° downward for optimal coverage).

Maintenance Features:

  • Card Management: The system allows for comprehensive management of RF card keys.
    • Up to 2,046 door release cards can be registered.
    • Individual cards can be deleted.
    • All registered cards can be deleted simultaneously.
    • A new master card registration will overwrite previous master card information.
  • Error Handling: The device provides auditory feedback (beep sound for 1.5 seconds) if the card registration memory is exceeded.
  • Safety Precautions: Users are advised to carefully read the user's guide, especially the precautions for safety, and follow instructions precisely to prevent accidents from abnormal operation. Only mini-type RF cards from COMMAX should be used. It is crucial not to turn off the device until all card deletion processes are completed to avoid data corruption.

Commax DRC-4UC/RF1 Specifications

General IconGeneral
Power SupplyDC 12V
Installation TypeSurface Mount
Wireless CapabilityYes
Power Source12V DC
Wiring2-wire
CameraYes
Mount TypeSurface Mount
Operating Temperature-10°C to 50°C
Operating VoltageDC 12V