EasyManua.ls Logo

Commercial Electric M1015B User Manual

Commercial Electric M1015B
12 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Item # 119 833
Model # M1015B
USE AND CARE GUIDE
We appreciate the trust and confidence you have placed in Commercial Electricthrough
the purchase of this analogue multimeter. We strive to continually create quality products
designed to enhance your home. Visit us online to see our full line of products available
for your home improvement needs. Thank you for choosingCommercial Electric!
ANALOGUE MULTIMETER
Table of Contents............................... 2
Safety Information 2...............................
Warranty .............................................3
Pre-Operation 4......................................
Operation 5..........................................
Maintenance 9.....................................
Care and Cleaning 11..........................
SAFETY SYMBOLS
Table of Contents
Safety Information
2
PRECAUTIONS
CAUTION: Set the range selection
switch to the desired function
prior to connecting test probes to
the Unit Under Test (UUT).
CAUTION: Only use the
multimeter within the
specified measurement ranges.
CAUTION: Before you use the
multimeter, verify that it
functions correctly (for
example, with a known voltage
source).
Symbol
Definition
This product is insulated at double insulation.
CAT ll
Symbol
Definition
Measurement category II, intended for
measurements performed on circuits directly
connected to the low voltage installation.
Examples are measurements on household
appliances, portable tools, and similar equipment.
This product conforms to ULSTD.61010-1.
Indicates important safety information.
Dangerous voltage may be present.
CAUTION: Prior to switching to a
new function or measurement
range, always disconnect the
measurement leads from the Unit
Under Test (UUT).
CAUTION: Only use the
multimeterin dry and clean
environments. Dirt and humidity
causes lower insulation
resistances and can lead to
electric shock in cases of higher
voltage.
CAUTION: Only use fuses of the
same type and characteristics.
Short-circuiting the fuse
holders is prohibited.
THANK YOU
Questions, problems, missing parts? Before returning to the store,
call Home Depot Customer Service
1- 877-527-0313
HOMEDEPOT.COM
Question and Answer IconNeed help?

Do you have a question about the Commercial Electric M1015B and is the answer not in the manual?

Commercial Electric M1015B Specifications

General IconGeneral
BrandCommercial Electric
ModelM1015B
CategoryMultimeter
LanguageEnglish

Summary

Safety Information

Safety Symbols

Explains safety symbols like danger, double insulation, and category ratings.

Precautions

Range Selection and Probe Connection

Instructions on setting range and handling probes before/after measurements.

Usage Environment and Fuse Safety

Warnings about using the multimeter in dry environments and proper fuse usage.

Pre-Use Verification

Emphasizes verifying the multimeter's correct function before use.

Operator Safety

General Safety Warnings and Precautions

Crucial warnings about reading the manual and safe handling of the instrument.

Safe Measurement Practices

Guidelines for probe condition, range selection, and avoiding current measurements with voltage.

Environmental and Fuse Safety Notes

Advice on avoiding shock, proper fuse limits, and environmental conditions.

Product Care Note

Recommendation to avoid direct sunlight to prevent overheating.

Warranty

Warranty Period and Conditions

Details the 12-month warranty and conditions under which it is void.

Pre-Operation

Package Contents

Lists all items included in the multimeter package with their descriptions.

Product Specifications

Details operating temperature, humidity, display, overvoltage category, and other technical specs.

Range and Accuracy

Provides a table of functions, ranges, and their respective measurement accuracy.

Operation

Measuring DC Voltage

Step-by-step guide on how to measure DC voltage using the multimeter.

Measuring AC Voltage

Step-by-step guide for measuring AC voltage, including scale selection.

Voltage Measurement Safety

Crucial warnings about exceeding voltage limits and probe disconnection.

Measuring Resistance

Detailed steps for measuring resistance, including zero adjustment and multiplier usage.

Measuring DC Current

Instructions for measuring DC current, emphasizing series connection and range selection.

Measuring Decibels

Guide to measuring decibels, including AC voltage range selection and calculation methods.

Checking the Battery

How to check the battery status using the multimeter's BAT function.

Maintenance

Calibration Interval Recommendation

Suggests periodic calibration for ensuring measurement accuracy and reliability.

Test Lead Replacement Guidelines

Specifies the required specifications for replacement test leads.

Replacing the Battery

Step-by-step instructions for replacing the multimeter's battery.

Replacing the Fuse

Procedure for replacing a blown fuse with correct specifications.

Care and Cleaning

Cleaning Instructions

Guidance on how to clean the instrument using a damp cloth, avoiding solvents.