EasyManua.ls Logo

Commercial Electric NOVA150-PC-4K-BZ - User Manual

Commercial Electric NOVA150-PC-4K-BZ
16 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
THANK YOU
We appreciate the trust and condence you have placed in Commercial Electric through the purchase of this LED area light. We strive to
continually create quality products designed to enhance your home. Visit us online to see our full line of products available for your home
improvement needs. Thank you for choosing Commercial Electric!
USE AND CARE GUIDE
NOVA COMMERCIAL LED AREA LIGHT
Questions, problems, missing parts? Before returning to the store,
call Commercial Electric Customer Service
9 a.m. - 5 p.m., EST, Monday - Friday
1-844-548-3776
HOMEDEPOT.COM
Item #1003 943 420
Model #NOVA150-PC-4K-BZ

Questions and Answers

  • M
    Maria SandersAug 12, 2025
    Why does my Commercial Electric NOVA150-PC-4K-BZ stay on?
    • J
      Jessica DiazAug 12, 2025
      If your Commercial Electric Outdoor Light stays on, it might be because the light sensor is in a shaded area. Try shining a flashlight into the light sensor and wait up to one minute. If the light turns off, relocate the fixture to an area with more daylight. Alternatively, place the optional black cover label over the photocell light sensor and use the wall switch to control the light. If the light does not turn off when a flashlight is shined on the light sensor for up to a minute, then the sensor may be faulty. Please contact customer service.
  • K
    Katherine ChambersAug 19, 2025
    How to fix a Commercial Electric Outdoor Light that does not turn on?
    • B
      Benjamin WilsonAug 19, 2025
      If your Commercial Electric Outdoor Light does not turn on, first ensure that the circuit breaker is not tripped and the wall switch is in the ON position. Also, verify that the wiring to the fixture is correct, remembering to turn the power OFF before checking the wiring. If these steps don't resolve the issue, the fixture might be sensing daylight. Cover the photocell and wait several seconds to see if the light turns on.
  • F
    ffitzpatrickAug 27, 2025
    What to do if my Commercial Electric NOVA150-PC-4K-BZ Outdoor Light flickers?
    • T
      Tara DavisAug 27, 2025
      If your Commercial Electric Outdoor Light is flickering, it might be connected to an unsuitable dimmer switch. Replace the current dimmer switch with a 0–10V dimming switch or a standard ON/OFF wall switch.
  • J
    Jeffrey DouglasSep 4, 2025
    Why my Commercial Electric Outdoor Light keeps turning on and off?
    • A
      adam84Sep 4, 2025
      If your Commercial Electric Outdoor Light cycles ON and OFF continuously, the photocell light sensor may be detecting reflected light. Try relocating the light fixture to a location where there is no reflected light. Alternatively, you can place the optional photocell cover over the photocell light sensor and use the wall switch to turn the light ON and OFF.