800W AUTOMATIC
PRESSURE PUMP
MODEL: PPT-800
INSTRUCTION MANUAL
0112
WARNING! Read all safety warnings and all instructions. Failure to follow
the warnings and instructions may result in electric shock, fire and/or serious
injury. Save all warnings and instructions for future reference.

Questions and Answers

  • J
    John CooperAug 11, 2025
    Why does my Commercial Electric Water Pump not start or pump water?
    • T
      Tara WardAug 11, 2025
      If your Commercial Electric Water Pump doesn't start or pump water, there are a couple of things to check: * First, ensure the pump is properly connected to the mains power supply. Disconnect the pump from the mains power and inspect the discharge outlet and filter. * Second, make sure the pump is also correctly connected to the water supply.
  • K
    Karen FosterAug 25, 2025
    Why is my Commercial Electric PPT-800 Water Pump operating intermittently?
    • M
      Melanie FischerAug 25, 2025
      If your Commercial Electric Water Pump operates intermittently, consider the following possible causes: * There may be a water leak in the household plumbing. Inspect and fix any leaks. * There might be insufficient air pressure in the tank. Empty the water from the tank and add air to 1.3 bar (19 psi) when no water is in the tank. * The voltage could be out of range. Ensure the pump is supplied with the voltage in accordance with the rating label requirements (230-240V). * Air flow may not be allowing the motor to cool. Make sure the pump is in a well-ventilated area. * The motor may be faulty or damaged. Contact Commercial Electric customer service.
  • T
    Taylor WrightAug 30, 2025
    How to fix tube or piping that won't stay on the male thread of my Commercial Electric PPT-800?
    • J
      jeremylindseyAug 30, 2025
      If the tube or piping does not stay on the male thread when water is travelling through your Commercial Electric Water Pump, it may be because the hose or tubing is worn or varies slightly in dimensions. To fix this, add a hose clamp to prevent leaks and secure the hose or pipe.
  • N
    Nancy StrongSep 4, 2025
    What to do if my Commercial Electric Water Pump has poor performance and low pressure flow?
    • S
      Sally HernandezSep 4, 2025
      If you're experiencing low pressure flow with your Commercial Electric Water Pump, it may be due to a faulty suction line. Check all suction lines for leaks or damage. Replace them if they are faulty, and ensure you are using a reinforced hose to prevent it from collapsing.
  • D
    Dr. Evelyn RichmondNov 16, 2025
    What to do if my Commercial Electric PPT-800 does not supply water when the motor is running?
    • M
      Makayla MercadoNov 16, 2025
      If your Commercial Electric Water Pump isn't supplying water despite the motor running, there could be several reasons: * The pump might not be primed. Fill the pump and suction line with water. * The suction line could be leaking. Inspect it for damage and replace if necessary. * The pump might be sucking in air. Make sure all connections and fittings are tightly secured. * The pump could be blocked. Disconnect the power and check the discharge outlet and filter for obstructions. * The pump might not be producing enough pressure. Inspect all pump parts, then clean and inspect the tank pressure. * The water source may be insufficient. Wait for the water source to replenish. * The suction height might be too high. Ensure it's no more than 8m. * The hose diameter might be to...