6
Following situations are normal
ź The flow of refrigerant through the evaporator may create a boiling or gurgling sound.
ź In the raining and high humidity weather, moisture may form on the outside of refrigerator or
door gaskets. You can wipe damp surfaces with dry cloth.
ź The temperature on the back panel may be high (particularly in summer) due to heat emission of
the condenser.
ź The temperature on external surface of the compressor may be high when compressor is wor-
king.
ź The compressor may cause a high hum or pulsating sound when it is at starting or stopping
step.
ź It's normal to hear metal hit noise from compressor when refrigerator is bumped.
Guidelines for protection of the environment
DISPOSAL: Do not dispose this product as unsorted municipal waste. Collection of such
waste separately for special treatment is necessary.
Meaning of crossed-out wheeled dustbin: Do not dispose of electrical
appliances as unsorted municipal waste. Use separate collection
facilities.
Contact your local government for information regarding the collection
systems available.
If electrical appliances are disposed of in landfills or dumps,
hazardous substances can leak into the groundwater and get into the
food chain, damaging your health and well-being.
Technical specification:
Type 07 087
Inner volume 45 L
Power supply 12 / 24 V =; 230 V ~
Power max. 45 W (3,75 A / 1,87 A)
Protection class III
Fuse 15A
Climatic class T/ST/N/SN
Energy rating A++
Category 1
Annual power consumption 73 kWh
Cooling rate +20°C to -20°C
Ambient temperature +10°C to +43°C
Noise level 46 dB(A)
External dimensions 63 x 39,8 x 52,4 cm
Cooling fluid R134a (40g)
Weight 13,5 kg
E