EasyManua.ls Logo

ComXim MT Series - Page 20

Default Icon
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MT series remote control intelligent turntable user guide
Copyright reserved by Shenzhen ComXim Technology Co., Ltd. 2017
19
8.2.1.3 Extended command
格式
参数数目
含义
CT+CAMERACTRL(focusOn
Off,captureOnOff);
1
Camera control
Focus On Off:
0: focus stop
1: focus start
Captures On Off:
0: stop taking photos
1: start taking photos
8.2.2 CR FeedbackEquipment -> Terminal
This feature can be turned on or off by "CT+ACK (on off);" command.
Format
Meaning
CR+OK;
Indicates that the turntable receives commands correctly.
CR+ERR=param;
Param for the error code, see the error code definition.
8.2.3 EventEquipment -> Terminal
This feature can be turned on or off by "CT+EVENT (on Off);" command.
Format
Meaning
CR+EVENT=param;
Param is event parameter:
CR+EVENT=TB_PAUSE; turntable pause.
CR+EVENT=TB_END; the action is complete.
8.2.4 Heartbeat mechanismEequipment < -> Terminal
Communication link detection between a device and a terminal. Through the device and the terminal mutual
communication link detection (heartbeat) bytes, to inform the other side of the connection status. This feature
can be turned on or off by "CT+HEARTBEAT (onOff);"
Format
Meaning
#or###
The equipments send heartbeat byte #" to each other.
Under normal circumstances, equipment sends a "#" byte to the terminal equipment each
second.
If the equipment did not receive a "#" byte for a long time (over 3s), and did not receive CT
command, it will enter the heart lost status and send a string"###" to inform terminal
heartbeat lost, until the equipment received "#" byte then it will exit heartbeat lost status.

Related product manuals