MT series remote control intelligent turntable user guide
Copyright reserved by Shenzhen ComXim Technology Co., Ltd. 2017
20
8.2.5 Error code
The error code is the parameter of the CR Feedback(CR+ERR=param).
This function can be turned on or off by command "CT+ACK (onOff);".
Command receive timeout error
The device does not support the command, or the command input
is incorrect.
CT command is ultra short, less than 5 characters (such as shorter
than the shortest command "CT ();")
CT command header error (if not for "CT"), pay attention to
Chinese and English input
CT command connection error (if not "+"), pay attention to
Chinese and English input
CT command parameters start with errors (if not "("), pay
attention to Chinese and English input
CT command parameter end error (if not), pay attention to the
input in English
CT command tail error (if not ";"), pay attention to Chinese and
English input
CT command name character is over length
CT command parameter is null character
CT command parameter character is over length
CT command number of parameters out limit
CT command number of parameters does not match
CT command parameters non numeric (71~79 corresponding to
the 1~9 parameters of the error)
The CT command parameter is a numeric value that goes beyond
the valid range (the 81~89 corresponding to the error of the first
1~9 parameter)
9 CT command common debugging tools
Users for the first time using the CT command, it is recommended to use the following sections of the
introduction of the third party Telnet tools, this chapter, respectively, SecureCRT, Windows super terminal as an
example.
Note: SecureCRT, Windows this product with non super terminal software, please users from legitimate
channels.