Please observe the following safety precau-
tions when using the air conditioner.
Failure or negligence in observing these safety
precautions could causere, electrical shock or
personal injury.
Precautions during installation
Please ask your sales agent or qualified techni-
cian for the installation of your unit. Water
leakage, short circuit orre may occur if you
install the unit by yourself.
Please use earth line.
Do not place the earth line near water or gas
pipes, lightning-conductor, or earth line of
telephone. Improper grounding could cause
electric shock.
A circuit breaker should be installed depending on
the mounting site of the unit. Without a circuit
breaker, the danger of electric shock exists.
Do not install near location where there is
flammable gas. The unit may catch fire if
flammable gas leaks around it.
WARNING
CAUTION
Precautions during operation
Avoid an extended period of direct air flow. It
could lead to health problems.
Do not modify the length of power cord or use an
extension cord. It could cause electrical shock or
fire.
Do not attempt to operate the unit with wet
hands, this could cause fatal accident.
Do not turn on the unit by inserting the power
cord.
Please switch off the unit and turn off the circuit
breaker during cleaning, the high speed fan
inside the unit may cause danger.
Turn off the circuit breaker if the unit is not
operated for a long period.
Do not splash or direct water to the body of the
unit when cleaning as it may cause short circuit.
Do not block the air intake and outlet vanes,
cooling performance will be affected.
CAUTION
SAFETY PRECAUTIONS
OWNER’S MANUAL
ROOM AIR CONDITIONER
OPERATION INSTRUCTIONS (Open the control door to access the controls)
OFF
This position stops all operations
of the air conditioner.
HIGH COOL
This position provides the
maximum air flow for rapid
cooling, dehumidifying and dust
removing operations (use this
position on sultry summer days).
FAN ONLY
This position provides fan operation alone
for air circulation and dust removal from
air.
Thermostat knob
The thermostat automatically starts and
stops the operation in order to keep the
room temperature at a proper level, and
this results in efficient use of power and
cooling. Turn the knob clockwise for cooler
temperature and counterclockwise for
warmer temperature settings.
MED COOL
This position provides the moderate air flow for
quiet cooling, dehumidifying and dust removing
operations (use this position when the outdoor
temperatures are likely to be lower).
LOW COOL
This position provides the minimum air flow for
quiet cooling, dehumidifying and dust removing
operations. (Suitable for night-time use)
Air Directional Louvers
The louvers will allow you to direct the air flow
Left or Right throughout the room as needed.
Move the Center handle from side to side until
the desired Left/Right direction is obtained.
Center handle
Selector knob
Question and Answer IconNeed help?

Do you have a question about the Condura ROOM AIR CONDITIONER and is the answer not in the manual?

Summary

Safety Precautions

Precautions during installation

Safety guidelines for installing the air conditioner to prevent hazards like electric shock or fire.

Precautions during operation

Safety measures to follow while operating the air conditioner to avoid health issues or electrical hazards.

Operation Instructions

Selector knob

Explains the different settings of the selector knob for various operating modes like OFF, HIGH COOL, MED COOL, and LOW COOL.

Thermostat knob

Details how the thermostat knob controls room temperature by automatically starting and stopping the unit.

Air Directional Louvers

Instructions on how to adjust the air directional louvers for directing airflow left or right within the room.

Air Conditioning Installation

Location

Guidance on choosing an appropriate location for the air conditioner, avoiding direct sunlight and ensuring structural support.

Dimension (Clearances)

Specifies the required installation hole size relative to the unit's outer wrapper dimensions for proper fit.

Care and Maintenance

Air Filter Cleaning

Step-by-step guide on how to clean the air filter to maintain airflow and cooling efficiency.

Troubleshooting Guide

Unit does not start

Troubleshooting steps for when the air conditioner fails to start, covering fuses, circuit breakers, and power connections.

Unit does not cool properly

Solutions for poor cooling performance, including checking the air filter, thermostat setting, and sunlight exposure.

Fan motor does not run

Steps to diagnose and fix issues where the fan motor is not operating, such as obstructions or bearing problems.

Ice or frost forms on the indoor coil

Advice on dealing with ice formation on the indoor coil, related to low temperatures, dirty filters, or system leaks.

Call Center and Regional Offices

Warranty Certificate

ONE YEAR WARRANTY ON PARTS AND LABOR

Outlines the manufacturer's warranty for one year covering defects in material and workmanship for parts and labor.

WARRANTY EXCLUSIONS

Lists conditions and circumstances under which the warranty coverage is not applicable.

FOUR YEAR LIMITED COMPRESSOR WARRANTY EXTENSION

Details an extended warranty specifically for the compressor unit for a period of four years.

Warranty Registration

Condura ROOM AIR CONDITIONER Specifications

General IconGeneral
BrandCondura
ModelROOM AIR CONDITIONER
CategoryAir Conditioner
LanguageEnglish