EasyManua.ls Logo

Cooper & Hunter Daytona CH-S09FTXD2 - User Manual

Cooper & Hunter Daytona CH-S09FTXD2
111 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
HEAT PUMP AIR TO AIR
Split Air Conditioner
M
ODELS
:
OWNER’S MANUAL
CH-S09FTXD2
CH-S12FTXD2
CH-S18FTXD2
CH-S24FTXD2
EN
For proper operation, please read and keep this manual carefully.
Designed by Cooper&Hunter International Corporation, Miami, FL, USA
CH-S09FTXD2-BL
CH-S12FTXD2-BL
CH-S18FTXD2-BL
CH-S24FTXD2-BL
DAYTONA SILVER SERIES
DAYTONA CARBON SERIES
CH-S09FTXD2-SC
CH-S12FTXD2-SC
CH-S18FTXD2-SC
CH-S24FTXD2-SC
DAYTONA SERIES
Question and Answer IconNeed help?

Do you have a question about the Cooper & Hunter Daytona CH-S09FTXD2 and is the answer not in the manual?

Summary

Explanation of Symbols

Exception Clauses

Manufacturer disclaims responsibility for personal injury or property loss due to improper use or external factors.

The Refrigerant

Refrigerant Information and Safety

Details on R32 refrigerant, its properties, safety, and installer qualifications.

Flammable Refrigerant Safety Operation

Installation, Maintenance, and Storage Notes

Guidelines for installation, maintenance, welding, refrigerant filling, and storage.

Safety Precautions: Installation

General Installation Safety

General safety guidelines and precautions to follow during the installation process.

Safety Precautions: Installation (Continued)

Installation Safety Measures

Further safety instructions and precautions for installing the air conditioner.

Safety Precautions: Operation and Maintenance

Operation and Maintenance Safety

Safety guidelines for operating and maintaining the air conditioner, including user responsibilities.

Safety Precautions: Operation and Maintenance (Continued)

Operational Safety Guidelines

Additional safety precautions related to operating and maintaining the air conditioner.

Installation Notice

Installation and Relocation Safety Precautions

Essential safety measures to follow when installing or relocating the air conditioner unit.

Tools for Installation

List of necessary tools required for the installation process.

Installation Location and Electrical Requirements

Location Selection and Basic Requirements

General requirements and places to avoid for installing the air conditioner unit.

Electrical Connection and Grounding

Guidelines for electrical connection, grounding, and air switch capacity.

Indoor Unit Installation Steps

Steps 1-5: Location, Frame, Piping, and Pipe Connection

Guidance on selecting location, installing frame, opening hole, and connecting pipes.

Indoor Unit Installation Steps (Continued)

Steps 6-7: Drain Hose and Wiring

Instructions for installing the drain hose and connecting electrical wiring.

Indoor Unit Installation Steps (Continued)

Steps 8-9: Pipe Binding and Unit Hanging

How to bind pipes and securely hang the indoor unit onto the wall-mounting frame.

Clean and Maintenance

Cleaning Procedures

How to clean the unit surface and filter, plus pre/post-season checks.

Error Code Troubleshooting

A list of error codes and their corresponding troubleshooting steps.

Troubleshooting Common Issues

Phenomenon Analysis and Solutions

Common issues like remote control problems, no air, or abnormal operation and their fixes.

Parts Identification and Display

Indoor Unit Components and Display Indicators

Identifies indoor unit parts and explains display indicators and icons.

Remote Controller Operation

Remote Controller Buttons and Display Icons

Visual guide to remote controller buttons and explanation of display screen icons.

Remote Controller Operation (Continued)

Detailed Button Functions

Detailed explanation of how to use various buttons on the remote controller.

Remote Controller Operation (Continued)

Mode and Adjustment Buttons

Explains Turbo, temperature adjustment, and swing angle selection buttons.

SLEEP Button Function

How to activate and use the Sleep mode for optimized comfort and energy saving.

Remote Controller Operation (Continued)

TIMER ON; TIMER OFF Button

How to set and cancel timer functions for automatic operation.

Remote Controller Operation (Continued)

Time, Quiet, WiFi, and Light Functions

How to set clock, activate quiet mode, manage WiFi, and control display light.

Health, Scavenging, and Temperature Display Functions

How to activate health/scavenging and switch temperature display modes.

Remote Controller Operation (Continued)

Special Function Buttons

Explains 8°C heating, child lock, dry contact, energy-saving, and temp display functions.

Remote Controller Operation (Continued)

Multi Timer and Self Clean Functions

How to set multiple timers and activate the double self-clean function.

Remote Controller Battery Replacement

Battery Replacement Notice

Important notes regarding remote controller operation and battery replacement.

Test and Operation

Post-Installation Checks and Testing Procedures

Checklist for verification after installation and procedure for testing operation.

Connection Pipe Configuration

Refrigerant Charging and Pipe Expanding

Details on refrigerant charging amounts and instructions for pipe expanding.

Connection Pipe Configuration (Continued)

Pipe Expansion Steps and Inspection

Detailed steps for pipe expansion, including burr removal, insulation, nut fitting, port expansion, and inspection.

Specialists Manual: Safety Checks

Refrigerant Installation and Electrical Component Safety

Checks for flammable refrigerants, electrical components, initial safety, and refrigerant presence.

Specialists Manual: Procedures

Component Repair, Cabling, Leak Detection, and Decommissioning

Guidelines for repairing components, checking cabling, leak detection, and decommissioning.

Specialists Manual: Recovery Procedures

Refrigerant Recovery Details

Further details on recovery equipment, cylinders, and handling recovered refrigerant.

Parts Identification

Outdoor Unit Components

Identifies and labels the main components of the outdoor unit.

Installation Notice and Safety

Installation and Relocation Safety and Tools

Critical safety measures for installation/relocation and list of required tools.

Installation Location and Electrical Requirements

Location Selection and Basic Requirements

General requirements for selecting an installation location, avoiding problematic areas.

Electrical Connection, Grounding, and Air Switch

Guidelines for electrical connection, grounding, and selecting appropriate air switch capacity.

Outdoor Unit Installation

Steps 1-4: Support, Drain Joint, Unit Fixing, and Pipe Connection

Instructions for fixing support, installing drain joint, fixing unit, and connecting pipes.

Outdoor Unit Installation (Continued)

Steps 5-6: Electrical Wiring and Pipe Neatening

Instructions for connecting electrical wiring and routing/securing pipes.

Test and Operation Procedures

Vacuum Pump Use and Leakage Detection

Steps for using a vacuum pump and methods for detecting refrigerant leaks.

Test Operation

Procedure for performing operational tests after installation and leak detection.

Cooper & Hunter Daytona CH-S09FTXD2 Specifications

General IconGeneral
TypeSplit System
Cooling Capacity9000 BTU/h
Coefficient of Performance (COP)4.0
Voltage220-240V
RefrigerantR32
InverterYes
Energy efficiency class (cooling)A++
Energy efficiency class (heating)A+
Operating Temperature (Heating)-15°C to 24°C
Power SupplySingle Phase
Noise level (indoor unit)22 dB
Air Flow (Indoor Unit)450 m3/h