Risk of Fire, Electrical Shock, Cuts or other Casualty Hazards- Installation and maintenance
of this product must be performed by a qualified electrician. This product must be installed
in accordance with the applicable installation code by a person familiar with the construction
and operation of
the product and hazards involved. For continued protection against shock hazard replace all
covers and guards after field wiring is completed.
Before installing or performing any service, the power MUST be turned OFF at the branch circuit
breaker. According to NEC 240-83(d), if the branch is used as the main switch for a fluorescent
lighting circuit,
the circuit breaker should be marked with “SWD”. All installations should be in compliance with the
National Electric Code and all state and local codes.
Risk of Personal Injury- Due to sharp edges, handle with care. Always use at least two people
when lifting and mounting heavy or large units
Failure to comply with these instructions may result in serious injury (including death) and property
damage.
WARNING
DISCLAIMER OF LIABILITY: Cooper Lighting Solutions assumes no liability for damages or losses of any
kind that may arise from the improper, careless, or negligent installation, handling or use of this product.
IMPORTANT: Read carefully before installing product. Retain for future reference.
NOTICE: Product may become damaged and/or unstable if not installed properly.
Note: Specifications and dimensions subject to change without notice.
ATTENTION Receiving Department: Note actual product description of any shortage or noticeable damage on
delivery receipt. File claim for common carrier (LTL) directly with carrier. Claims for concealed damage must
be filed within 15 days of delivery. All damaged material, complete with original packing must be retained.
NOTICE: If a room is wired for two circuits using two separate hot leads, it is very important to connect only
one circuit per relay. Both circuits must be fed from the same phase.
NOTICE: Ensure that all modules are firmly seated on the DIN rails before beginning field wiring.
NOTICE: The high voltage supply should be fed to the cabinet via an external isolation breaker with sufficient
capacity for the planned installation.
NOTICE: Ensure that the supply is fully isolated at an external breaker before opening doors. Test that power
has been removed before starting to handle conductors.
NOTICE: Ensure that high voltage and low voltage wiring remains separate.
NOTICE: All new wiring must be fully verified before applying power.
NOTICE: Designed for indoor installation and use only. Dry location rated.
TSE55-B Color Touchscreen
Installation Instructions
Installation guide
TSE55-B Color Touchscreen
Question and Answer IconNeed help?

Do you have a question about the Cooper TSE55-B and is the answer not in the manual?

Cooper TSE55-B Specifications

General IconGeneral
Touch TechnologyCapacitive
Multi-touchYes
InterfaceUSB
Aspect Ratio16:9
Brightness250 cd/m²
Contrast Ratio800:1
Response Time5 ms
Weight200g
Display Size5.5 inches
Screen Size5.5 inches
Power SupplyDC 5V
Operating Temperature-10°C to 60°C
Operating System CompatibilityWindows, Linux, Android
Storage Temperature-20°C to 70°C

Summary

Important Safety Warnings

Electrical Shock and Fire Hazards

Installation by qualified electrician, follow codes, replace covers for shock protection.

Personal Injury Risks

Handle with care due to sharp edges, use two people for heavy units to prevent injury.

General Notices and Disclaimers

Read before installing, retain for reference. Product may be unstable if not installed properly.

Planning the Installation

Mounting Orientation and Depth

Designed for wall mounting in Portrait or Landscape. Requires 1 inch mounting depth plus cable space.

Power and Network Connection

Powered by PoE (IEEE 802.3af) and connects to the local network via a hard-wired Ethernet connection.

Recommended Mounting Height

Installation Steps

Back Box Compatibility

Mounts to Standard UK, European, or US NEMA single gang back boxes with minimum 47mm depth.

Mounting Frame Installation

Attach the included mounting frame to the back box using screws supplied with the back box.

Mounting the TSE55-B Unit

Attaching Unit to Mounting Bracket

Align mounting frame hooks with unit slots and gently push the unit onto the bracket until engaged.

Securing the TSE55-B

Tighten the two captive screws, one on each side, to firmly secure the TSE55-B to the mounting bracket.

PoE Connection and Ethernet

PoE Standard Requirements

Requires IEEE 802.3af standard network switch or PoE injector for power and data connectivity.

Connecting Ethernet Cable

Use a standard CAT5E or CAT6 Ethernet cable from the network switch to the LAN/PoE jack on the unit.

Connecting to the Lighting Network

Removing the TSE55-B

Specifications

Physical Dimensions and Display

Dimensions: 5.8" W x 3.42" H. Mounting depth: 0.86". Display: 5.5" Diagonal, 1280 x 720 resolution.

Network and Power Requirements

Network: 10/100/1000 Ethernet. Power via PoE (IEEE 802.3af, 13W) or 24V DC PSU (0.5A).

Warranty and Compliance

Product Warranty Information

Limited warranty for defects in material/workmanship. Excludes damage from misuse, accident, or improper installation.

Compliance and Usage Standards

Use in accordance with National Electrical Code, UL, and industry standards. Non-compliance can be hazardous.