29
Operation and Installation Manual for
COPA Nixa12 Hermetic Water Heater
8.0. Technical Specifications Table for Copa Nixa 12
Nixa12
kW 10,0 / 23,5
kW 8,5 / 21,1
% 89,2 / 88,1
m
/h 1,03 / 2,43
NOx Sınıf 6
NOx mg/kWh 37,7
Class A
% 77
L
ΔT= 25 °C) l/dak. 12
l/dak. 3
bar 8
bar 0,5
°C 35 - 60
dB 48
IPX4D
W 20-30
mm 645x320x250
51,6
kg 15
Gross Weight
Chimney Type
kg 17
C12,C62
Rated Heat Load (Minimum/Maximum)
Technical Data Unit
Rated Heat Power (Minimum / Maximum)T
Yield (Minimum / Maximum)
Natural Gas Consumption (Minimum / Maximum)
Seasonal Efficiency Class
Efficiency Class
Hot Water Load Profile
Capacity
Minimum Water Flow
Water Pressure Maximum
Water Pressure Minimum
Setting Range
Sound
Electrical Protection Class
Electricity Consumption
Dimensions
Volume
Net Weight
Load Profile
Liter