Trouble Possible Causes Solution
The axles cant work when
operating the machine
Poor contact of the electrical
equipment
Check the Plug
The mixing bowl is out of position Moving direction is not correct Change
Leaks oil Sealing washer is damaged Change
Clean the slideway and lubricate
The motor is overheated
and speed is down
The voltage is not enough, or
incorrect speed
Check the voltage or use
lower speed
Noise and overheating Poor lubrication Add or change lubrication
Mixer touches bowl The mixing device or bowl de -
formed
Repair or change the bowl
or mixing device
Limited Warranty
Cleaning
DISCONNECT THE MACHINE FROM THE POWER SOURCE BEFORE CLEANING.
!
All new mixer bowls and accessories including, whips, beaters and dough hooks should be properly washed before use.
n with
clean water. It is highly recommended this cleaning procedure is followed for bowls and accessories prior to whipping egg whites or
whole eggs. The mixer should be cleaned daily with a clean damp cloth.
If the unit has not been used for some time it is recommended that the procedure above is followed before mixer use.
It is important that the rear bowl lift guides are greased every three months to prevent corrosion.
WARNING:
10
Royal-Kincool Refrigeration Equipment Co., Ltd
Version: 1.0
Juice dispenser model: Corolla series, English manual
Released date: 2005.10.27
Connecting to a fresh life
Trouble shooting:
Symptom
Possible reasons
Solution
Remark
No power to
machine
Plug is not in.
Insert plug into mains socket
Main switch is not on the “I”
position.
Switch main switch to “I” position.
Power cord is broken.
Replace power cord
Ask for
authorized
service
department
to check and
repair it.
Main switch is broken.
Replace main switch
Machine is
not cooling
Compressor does not start
See “compressor does not start”
section.
Gas leak into the cooling
circuit.
Find leak, filter it out and re-charge
the cooling circuit
Condenser is clogged.
Clean the condenser
Fan motor is burnt.
Replace fan motor
Lack of air flow
Increase distance between the
machine and other obstacles /
heating sources
Compressor
does not
start
Main switch is broken
Replace main switch
Ask for
authorized
service
department
to check and
repair it.
Compressor protector is
broken.
Replace compressor protector
Compressor relay is broken
Replace compressor relay
Compressor motor is broken
Replace motor
One tank is
not cooling
Gas leak into the cooling
circuit
Find leak, filter it out and re-charge
the cooling circuit
Condenser is clogged
Clean the condenser
Lack of air flow
Increase distance between the
machine and other obstacles /
heating sources
Tube of the cooling circuit is
clogged.
Cut the tube, eliminate clog,
re-charge the cooling circuit
Filter is clogged
Replace the filter
The mixing
paddles are
not working
The mixing motor is broken
Replace the mixing motor
The pump
not working
The pump motor is broken
Replace the pump motor
The pump switch is broken.
Replace the pump switch
Warning: If the appliance has any problem or has been damaged, do not try to repair or
replace it by yourself. Please ask for the authorized service department for help.
Manufacturer: Royal-Kincool Refrigeration Equipment Co.,
Trouble Possible causes Solution
Any necessary repairs to the machine should be undertaken exclusively by an authorized repair
center,using original replacement parts.
The electrical cord should not be replaced by the user.
When the machine is no longer in use, it is recommended that it be made inoperable by
unplugging the machine and cutting the electrical cord.