The capacity of the dryer seems
to be low
Low ambient temperature or
low relative air humidity.
The air flow is heavily reduced
because of dirty filter.
If the dehumidifier is used with
a hygrostat, this may be
incorrect or incorrectly set to
too high a relative humidity.
During the time it has been
installed, the machine has
stopped on numerous
occasions because of either too
high or low ambient
temperature.
Check relative air humidity.
Increase the temperature in
the area.
Replace the filter.
Check the external hygrostat
function by raising and
lowering its setpoint and note
that the machine switches off
and on.
Ensure that the temperature is
kept within the machine's
operating range, 9 °C to 38 °C,
and note that the capacity
increases with increasing
temperature.
Operating temperature range, °C
Dehumidification, max., litres per 24 hours
Dehumidification at 30°C, 80% RH, litres per 24 hours
Dehumidification at 20°C, 60% RH, litres per 24 hours
Supply voltage, 1 phase, 50Hz, V
Dimensions, length x width x height, mm
Noise level, dB (A) 3m high speed
Noise level, dB (A) 3m low speed