V150921
Touch-Panel Controller + Reader
Networking & Stand-alone
※
Mode 6 the number of users up to 65535, largely because of its read-only CARD CODE, unlike Mode4/Mode8 shall read the SITE CODE and CARD CODE.
Mode Support
Networking/
Stand-Alone
Stand-Alone
Networking/
Stand-Alone
User
Capacity
Access Mode
M4
M6
M8
V
X
V
V
X
V
V
X
V
V
X
V
32
X
32
11
X
11
1,500
X
1,500
3,000
65,535
3,000
Auto-show
Duty time
Event
Capacity
120 Holidays Duress
Time
Zone
Lift
Control
Anti-pass-
back
1.Card only
2.Card and PIN (4-digit individual PIN)
3.Card or PIN (if access by PIN only, user should press 9-digit PIN = 5-digit user
address + 4-digit individual PIN)
1.Card only
2.Card and PIN (4-digit public PIN= Arming PWD)
3.Card or PIN (4-digit public PIN= Duress code)
P.S. Duress code is unavailable under M6 and as PWD of PIN only
1.Card only
2.Card and PIN (4-digit individual PIN)
3.Card or PIN (if access by PIN only, user could just press 4-digit individual PIN)
Device enable
Access programming mode
→
20 128 [Please refer to function default value for details.]
Enable/Disable auto open zone
Access programming mode
→
20 004 [Please refer to function default value for details.]
Enable/Disable auto open door without presenting card
Access programming mode
→
24 001 [Please refer to function default value for details.]
[i.e.] User address from 00152 to 00684 enable the anti-pass-back function:
26 00152 00684 0
Card user enable
Access programming mode
→
26 SSSSS EEEEE N
N: 2 sets of auto-open zone (N=0=1st set; N=1=2nd set); HHMMhhmm=Staring time to ending time (i.e.: 08301200=08:30 to 12:00);
FFFFFFF= 7 days of week (Sat/Fri/Thu/Wed/Tue/Mon/Sun) (F= 0: disable; 1: enable)
Setting up open time
Access programming mode
→
08 N HHMMhhmm FFFFFFF
Usually, anti-pass-back is commonly applied to parking areas in order to prevent from multi-entry with one card at a time, or somewhere wants to monitor not only the access but also exit condition.
Door will keep opening after rst man ashing card. When Stand-Alone, support only two sets of auto-open zone by device setting, but auto-open zone can extend up to 63 sets by Networking.
Need the other Reader to do this Function
Access programming mode
→
28 064 [064= Dual Door Open]
Access programming mode
→
04 N [N=4/6/8]
E. Dual Door Open(M4/M8)
F. Anti-pass-back(M4/M8)
G. Auto Open Zone
D.Setting up the control mode (M4/M6/M8)
H. Lift control
Device Enable
Access programming mode
→
24 002 [Please refer to function default value for details.]
[i.e.] User address NO. 45, only to the six oor, with the 20th oor:
Access programming mode
→
21 00168 0 00100000
→
21 00168 2 00001000
Multi oors
Access programming mode
→
21 UUUUU S FFFFFFFF
[UUUUU=User address S: 4 sets of lift control (Input: 0~3) FFFFFFFF: 8 oors/stop setting (F=0=Disable, F=1=Enable)]
Single oor
[i.e.] User address NO. 45, only can reach the elevator to the 24th oor:
27 00045 24
Access programming mode
→
27 UUUUU FF [UUUU=User Address FF=Floor number (01~32 oor/stop)]
Connect with ACC1040 to control which oors the user will be able to access.
Set
Floor/ Stop
F
8
16
24
32
0
1
2
3
F
6
14
22
30
F
7
15
23
31
F
5
13
21
29
F
4
12
20
28
F
3
11
19
27
F
2
10
18
26
F
1
9
17
25
Please refer to below oor chart
Setting up the alarm
Under what conditions would trigger alarm systems
Flow chart
Enable/ Disable the arming status(M4/M8)
Enable/ Disable the arming status(M6)
Enable
Access programming mode
→
Conditions:
1. Arming enabled
2.Alarm system connected
Disable
Access programming mode
→
Application:
1. Door opened too long (After Normal Opening): Door Opened over the time of door relay time and door close time.
2. Door sensor error: Door sensor is open loop.
3. Force open (Opened without a valid user card being show): Access by force open and illegal procedure.
About Alarm System
Function
Door Relay TM
Door Close TM
Alarm Relay TM
Alarm Delay TM
Arming Delay TM
Force Opem
Command
02
18
03
06
05
28
1
2
4
3
1
2
By ashing card + Arming PWD
Enable/Disable: Flash card +press 4 digit arming PWD PPPP (default: 1234)
1. Arming PWD= 0000: Cancel Arming PWD
2.
Arming PWD≠ 0000: Flash card +press 4 digit arming PWD +
I.Restoring Factory Settings
Only a function of factory default value. (At Stand-Alone)
Access programming mode
→
20
016
→
24
064
→
26
00000
01023
1
→
28
000
→
29
29
※
If Master Code already changed, it can not revert to the default value.
A.Normal Opening:
Door Opened
Enable Arming Arming Delay TM
Enable Arming Arming Delay TM
Alarm system activated
Arming settingArming setting Alarm triggerAlarm trigger
Door opened
Timeout
Door opened Timeout
Alarm system activated
Arming settingArming settingAlarm triggerAlarm trigger
B.Abnormal Opening:
Alarm Delay TM
1 Alarm Relay TM2
Door Relay TM
1 Door Close TM2 Alarm Delay TM3 Alarm Relay TM4